Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2128108.1
Update Date:2017-09-22
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2128108.1 :   SPT-8002-AR - the chassis intrusion detector has been triggered  


Related Items
  • ILOM (Integrated Lights Out Management)
  •  
  • Netra SPARC S7-2
  •  
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • MiniCluster S7-2 Hardware
  •  
  • SPARC T7-4
  •  
  • SPARC S7-2L
  •  
  • SPARC S7-2
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

ILOM (Integrated Lights Out Management)
MiniCluster S7-2 Hardware
Netra SPARC S7-2
SPARC S7-2L
SPARC S7-2
SPARC

Purpose

 Provide additional information for message ID: SPT-8002-AR

Details

Type: Alert

   alert.ilom.chassis.security.enclosure-open

Severity: Major

Description:

The chassis enclosure security detector has been activated.

Automated Response:

The service required LED on the chassis will be illuminated.

Impact:

The server will power off immediately and the Service Processor will be in degraded mode.

Suggested Action for System Administrators:

This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response.

NOTE: This message ID will not result in a service request being automatically submitted by ASR.

 