Solution Type Predictive Self-Healing Sure Solution 2128108.1 : SPT-8002-AR - the chassis intrusion detector has been triggered
In this Document
Applies to:ILOM (Integrated Lights Out Management)MiniCluster S7-2 Hardware Netra SPARC S7-2 SPARC S7-2L SPARC S7-2 SPARC PurposeProvide additional information for message ID: SPT-8002-AR DetailsType: Alert alert.ilom.chassis.security.enclosure-open Severity: Major Description: The chassis enclosure security detector has been activated. Automated Response: The service required LED on the chassis will be illuminated. Impact: The server will power off immediately and the Service Processor will be in degraded mode. Suggested Action for System Administrators: This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response. NOTE: This message ID will not result in a service request being automatically submitted by ASR.