![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2128102.1 : SPT-8002-C4 - AC input failure
In this Document
Applies to:MiniCluster S7-2 HardwareILOM (Integrated Lights Out Management) SPARC S7-2 SPARC S7-2L Netra SPARC S7-2 SPARC PurposeProvide additional information for message ID: SPT-8002-C4 DetailsType: Alert alert.ilom.chassis.power.loss Severity: Major Description: A power supply has detected an AC input power failure. Automated Response: The service required LEDs on the chassis and the affected power supply/supplies will be illuminated. Impact: If insufficient operational power supplies are available the server will power off. Suggested Action for System Administrators: This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response.
Attachments This solution has no attachment |
||||||||||||||
|