![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2128072.1 : SPT-8002-8Q - a FRU is in an unsupported location
In this Document
Applies to:ILOM (Integrated Lights Out Management)MiniCluster S7-2 Hardware Netra SPARC S7-2 SPARC S7-2L SPARC S7-2 SPARC PurposeProvide additional information for message ID: SPT-8002-8Q DetailsType: Alert alert.ilom.chassis.config.component.misconfigured Severity: Major Description: A FRU has been inserted into a location that does not support the FRU. This can include, but is not limited to, unsupported cpu/memory boards, memory DIMMs, HDD or SSD devices in a disk backplane, power supplies, service processors or PCIe cards in PCIe carriers, Automated Response: The service required LED may be illuminated on the chassis. Impact: The device may not be usable in its current location and/or the host may not boot successfully. Suggested Action for System Administrators: This event is essentially informational in nature and may not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response. Attachments This solution has no attachment |
||||||||||||||
|