![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2122955.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.160419 (Linux - Virtual) for April 2016
In this Document
Applies to:Exalogic Elastic Cloud X3-2 HardwareExalogic Elastic Cloud X4-2 Hardware Exalogic Elastic Cloud X5-2 Hardware Oracle Exalogic Elastic Cloud X2-2 Hardware Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 to 2.0.6.2.4 Linux x86-64 Oracle Virtual Server(x86-64) PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around April 2016 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNote:
Patch Download
Released: April 2016 Product Version: 2.0.6.2.160419 (on X2-2/X3-2/X4-2/X5-2) for Oracle Exalogic Elastic Cloud infrastructure PATCH 22584289 - EXALOGIC VIRTUAL 2.0.6.2.160419 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR APRIL 2016 Patch Readme DocumentationRefer to the readme documentation attached 22584289-Virtual.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 22584289-Virtual.zip: 22584289-Virtual
Prerequisite Important: Before patching, verify that the cluster heartbeat timeout is set correctly, as documented in the Document ID : 1995593.1 - Increase O2CB Cluster Heartbeat Timeout on Exalogic Virtual
INTERNAL Pre-requisites PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racks Refer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Doc ID 2122959.1: Exalogic Infrastructure April 2016 PSU – Fixed Bugs List Appendix B: Patching Known IssuesCompute node patching fails with error "unable to determine total RAM failed"Please review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1) Upgrading NM2 Switch Firmware on full rack Exalogic systems or multi-rack Exa systems causing Network outagePost NM-2 switch upgrade in a virtual environment, vServer creation may failPlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1)Post NM-2 switch upgrade in a virtual environment, vServer creation may timeoutPlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1)Exareport: Display issues with previously backed up index filesPlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1)ZFS patching fails due to losing IO access to the poolpsuSetup.sh failing due to lack of free spacePlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1)PCIE fault HW alert in ZFS post IB firmware updatePlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1)Exalogic: ZFS-7320 ILOM Network Settings Lost on X2-2 and X3-2 Racks After PSU UpgradePlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1) The NM2-GW firmware upgrade to version 2.1.8-1 for Switches Fails Using ExapatchPlease review Exalogic: NM2-GW Firmware Upgrade To Version 2.1.8-1 For Switches Fails Using Exapatch (Doc ID 2149792.1) Exapatch Pre-patch Check for Exalogic Control Services Fails Regardless of the Availability of Recent ExaBR BackupsPlease review Exalogic Infrastructure PSU Upgrade - Known Issues (Doc ID 1571367.1) Exalogic vServer April 2016 PSU Upgrade is Failing with : Protected multilib versions: libjpeg-turbo-1.2.1-3.el6_5.x86_64 != libjpeg-turbo-1.2.1-1.el6.i686Exalogic : vServers Stuck In Single User Mode When Applying PSU In Parallel On Multiple vServersRefer to <Note 2213470.1> on this issue.
Appendix C: FAQsInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingRefer to <Note 1997466.1> for details Guest vServer patching FAQ'sRefer to <Note 2031749.1> for details. References<NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note<NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues <NOTE:2122959.1> - Exalogic Infrastructure April 2016 PSU – Fixed Bugs List <NOTE:2149792.1> - Exalogic: NM2-GW Firmware Upgrade To Version 2.1.8-1 For Switches Fails Using Exapatch <NOTE:2213470.1> - Exalogic : vServers Stuck In Single User Mode When Applying PSU In Parallel On Multiple vServers Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|