FMA Event ID |
Severity
|
Knowledge Doc ID
|
Description |
AK-8000-0M |
2 |
|
|
AK-8000-86 |
2 |
1168273.1 |
The service processor needs to be reset to ensure proper functioning |
AK-8000-9T |
2 |
1579286.1 |
The appliance kit failed to initialize |
AK-8000-CN |
3 |
1579287.1 |
The appliance mgmt interface was reset after it became unresponsive and timed out |
AK-8000-DG |
2 |
1579289.1 |
The appliance mgmt interface unresponsive and the appliance had to be rebooted |
AK-8000-H7 |
2 |
1491956.1 |
"The JBOD '' is configured incorrectly" is reported |
AK-8000-H7 |
2 |
1542500.1 |
Mismatched SIM Firmware (FW) |
AK-8000-H7 |
2 |
1579300.1 |
A ZFS Appliance disk is configured incorrectly |
AK-8001-79 |
2 |
|
|
AK-8001-F7 |
2 |
|
|
AK-8001-GU |
2 |
1456741.1 |
Service Processor has stopped responding to requests |
AK-8001-GU |
2 |
1579302.1 |
The service processor has stopped responding to requests |
AK-8001-U1 |
2 |
1579303.1 |
A cluster peer state error has been detected |
AK-8001-W7 |
3 |
1579304.1 |
The cluster peer has failed and reset |
AK-8002-RU |
3 |
|
|
AK-8003-UG |
2 |
1579305.1 |
Fibre Channel connectivity has been lost on one or more ports |
AK-8003-W9 |
3 |
1579306.1 |
Multiple transient Fibre Channel state changes on a port |
AK-8003-Y6 |
3 |
1553287.1 |
The device configuration is invalid. |
AK-8004-08 |
2 |
1564538.1 |
Incompatible drives installed |
AK-8004-1M |
2 |
1545768.1 |
A power supply is installed in the incorrect slot |
AK-8004-27 |
3 |
1546894.1 |
Configuration mismatch of Logzilla drive types |
AK-8004-3U |
2 |
1545785.1 |
EBOD not fully populated; Unsupported partially populated DE2-24P |
AMD-8000-1W |
2 |
1021122.1 |
Memory module errors exceeding acceptable levels |
AMD-8000-2F |
2 |
1021123.1 |
Memory module correctable errors exceeding acceptable levels |
AMD-8000-3K |
2 |
1021124.1 |
Memory module correctable errors exceeding acceptable levels |
AMD-8000-48 |
2 |
1021125.1 |
Multibit memory module errors |
AMD-8000-5M |
2 |
1021127.1 |
CPU errors exceeded acceptable levels |
AMD-8000-67 |
2 |
1021128.1 |
CPU errors exceeded acceptable levels |
AMD-8000-7U |
2 |
1021129.1 |
CPU errors exceeded acceptable levels |
AMD-8000-8L |
2 |
1021130.1 |
CPU errors exceeded acceptable levels |
AMD-8000-9G |
2 |
1021131.1 |
CPU errors exceeded acceptable levels |
AMD-8000-AV |
2 |
1021132.1 |
CPU errors exceeded acceptable levels |
AMD-8000-C0 |
2 |
1021133.1 |
CPU errors exceeded acceptable levels |
AMD-8000-DT |
2 |
1021134.1 |
CPU errors exceeded acceptable levels |
AMD-8000-E6 |
2 |
1021135.1 |
CPU errors exceeded acceptable levels |
AMD-8000-FN |
2 |
1021136.1 |
CPU errors exceeded acceptable levels |
AMD-8000-G9 |
2 |
1021137.1 |
CPU errors exceeded acceptable levels |
AMD-8000-HK |
2 |
1021138.1 |
CPU errors exceeded acceptable levels |
AMD-8000-JF |
2 |
1021139.1 |
CPU errors exceeded acceptable levels |
AMD-8000-KW |
2 |
1021140.1 |
A Fault In A DRAM Channel |
AMD-8000-L1 |
2 |
1021190.1 |
Memory Module Has Failed BIOS Test |
AMD-8000-MU |
2 |
1021191.1 |
Errors from a single page exceeding acceptable levels |
AMD-8000-N7 |
2 |
1021192.1 |
Errors from a single page exceeding acceptable levels |
AMD-8000-PM |
2 |
1021193.1 |
Errors from a single page exceeding acceptable levels |
DISK-8000-0X |
2 |
1021141.1 |
Predictive Disk Failure Imminent |
DISK-8000-12 |
2 |
1021142.1 |
Disk Temperature Exceeded Threshold |
DISK-8000-2J |
2 |
1021143.1 |
Disk Self-Test Failure |
DISK-8000-3E |
3 |
1021144.1 |
A non-recoverable hardware failure was detected by the device while performing a command |
DISK-8000-4Q |
3 |
1021145.1 |
SCSI fault for media: terminated with a non-recovered error condition |
DISK-8000-D5 |
2 |
1427614.1 |
There have been excessive transient ZFS checksum errors on this disk. |
DISK-8000-6R |
3 |
1382747.1 |
A path to the device has been unconfigured due to transport instability |
DISK-8000-74 |
2 |
1427579.1 |
There has been a non-recovered medium read error |
DISK-8000-8D |
2 |
1427593.1 |
There has been a non-recovered medium write error |
FMD-8000-0W |
2 |
1021146.1 |
Solaris Fault Manager Received Unexpected Event |
FMD-8000-11 |
2 |
1021147.1 |
Solaris Fault Manager unable to determine message summary |
FMD-8000-2K |
2 |
1021148.1 |
Solaris Fault Manager component had disabling error |
FMD-8000-3F |
2 |
1021149.1 |
Solaris Fault Manager component has erroneous configuration file |
GMCA-8000-21 |
3 |
1021154.1 |
Level 0 CPU Cache Fault |
GMCA-8000-47 |
3 |
1021156.1 |
Level 2 CPU Cache Fault |
GMCA-8000-5U |
3 |
1021157.1 |
CPU Cache Fault |
GMCA-8000-MM |
3 |
1021201.1 |
Level 2 Data Cache Fault |
GMCA-8000-N8 |
3 |
1021206.1 |
Data Cache Fault |
GMCA-8000-SL |
3 |
1021215.1 |
Instruction Cache Fault |
GMCA-8000-UV |
3 |
1021235.1 |
Memory fault |
GMCA-8000-YN |
3 |
1021245.1 |
Memory module correctable errors exceeding acceptable levels |
MPT-8000-0S |
2 |
1115005.1 |
Remediation of PCI Express 8-Port Host Adapter (Pandora) B3 cards with C0 cards. |
NAS-8000-5H |
2 |
|
|
NXGE-8000-0U |
2 |
1021161.1 |
NXGE XFP Optical Transceiver Fault |
NXGE-8000-17 |
2 |
1021162.1 |
XAUI Fault |
PCIEX-8000-0A |
2 |
1021223.1 |
PCIEX subsystem problem |
PCIEX-8000-1P |
2 |
1021224.1 |
PCIEX subsystem problem |
PCIEX-8000-25 |
2 |
1021225.1 |
PCIEX subsystem problem |
PCIEX-8000-3S |
2 |
1022184.1 |
PCIEX subsystem problem |
PCIEX-8000-43 |
2 |
1021305.1 |
PCIEX subsystem problem |
PCIEX-8000-5Y |
2 |
1021306.1 |
PCIEX subsystem problem |
PCIEX-8000-6D |
2 |
1021307.1 |
PCIEX subsystem problem |
PCIEX-8000-7H |
2 |
1021309.1 |
PCIEX subsystem problem |
PCIEX-8000-8R |
2 |
1021310.1 |
PCIEX subsystem problem |
PCIEX-8000-94 |
2 |
1021312.1 |
PCIEX subsystem problem |
PCIEX-8000-AQ |
2 |
1021313.1 |
PCIEX subsystem problem |
PCIEX-8000-CC |
2 |
1021314.1 |
PCIEX subsystem problem |
PCIEX-8000-DJ |
2 |
1021316.1 |
PCIEX subsystem problem |
PCIEX-8000-EE |
2 |
1021317.1 |
PCIEX subsystem problem |
PCIEX-8000-FX |
2 |
1021320.1 |
PCIEX subsystem problem |
PCIEX-8000-G2 |
2 |
1021321.1 |
PCIEX subsystem problem |
PCIEX-8000-HS |
2 |
1022183.1 |
PCIEX subsystem problem |
SENSOR-8000-1N |
3 |
1257154.1 |
Power supply failed |
SENSOR-8000-26 |
3 |
1262238.1 |
Fan failed |
SENSOR-8000-3T |
3 |
1262178.1 |
Power supply failed |
SENSOR-8000-7L |
3 |
1262258.1 |
External condition causing power supply failure |
SENSOR-8000-8U |
2 |
|
|
SENSOR-8000-AM |
2 |
|
|
SUNOS-8000-20 |
2 |
1021440.1 |
SUNOS subsystem or controlling software problem |
SUNOS-8000-3V |
2 |
1021442.1 |
PCI subsystem problem |
SUNOS-8000-46 |
2 |
1021443.1 |
PCI subsystem or its controlling software problem |
SUNOS-8000-5T |
2 |
1021444.1 |
PCI bus or controlling software problem |
SUNOS-8000-69 |
2 |
1021452.1 |
PCI controller problem |
SUNOS-8000-7N |
2 |
1021461.1 |
PCI bus problem |
SUNOS-8000-8W |
2 |
1021462.1 |
PCI controller software problem |
ZFS-8000-D3 |
3 |
1021617.1 |
ZFS device failure |
ZFS-8000-FD |
3 |
1021619.1 |
Too many I/O errors on ZFS device |
ZFS-8000-GH |
2 |
1021621.1 |
Too many checksum errors on ZFS device |
ZFS-8000-HC |
3 |
1021622.1 |
ZFS pool I/O failures |
ZFS-8000-K4 |
3 |
1021625.1 |
ZFS intent log read failure |
ZFS-8000-QJ |
3 |
1480040.1 |
Missing data on ZFS device. Applications are unaffected if sufficient replicas exist |