Solution Type  Predictive Self-Healing Sure

Solution  2116689.1 :   Oracle ZFS Storage Appliance: How to Lookup ASR Fault Message IDs  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun Storage 7720 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Purpose
Details
 How to view the 'fault' list in the BUI
 How to view the 'fault' list in the CLI
 How to view the 'fault detail in the CLI
 List of ASR fault message IDs and links to related knowledge resources
References


Applies to:

Sun Storage 7720 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7110 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Purpose

This document lists all the FMA fault messages with links to the specific Knowledge documents related to the Oracle ZFS Storage Appliance.

 

Details

How to view the 'fault' list in the BUI

Enter the appropriate Appliance IP address into a browser ; eg.  http://<NAS_IP_ADDRESS>:215

Login to the BUI using the appropriate username and password.

Go to the Maintenance > Problems page

Select/highlight the specific fault

 

BUI fault list

 

How to view the 'fault' list in the CLI

Log in as root (for example:  ssh root@<NAS_IP_ADDRESS> ) and then using the CLI execute the following:

        CLI> maintenance problems show

 

CLI fault list

 

How to view the 'fault detail in the CLI

Select the appropriate problem :

        CLI> select problem-XXX

...then run show

 

 CLI fault detail

 

List of ASR fault message IDs and links to related knowledge resources

FMA Event ID     Severity  
Knowledge Doc ID  
 Description
AK-8000-0M 2    
AK-8000-86 2 1168273.1 The service processor needs to be reset to ensure proper functioning
AK-8000-9T 2 1579286.1 The appliance kit failed to initialize
AK-8000-CN 3 1579287.1 The appliance mgmt interface was reset after it became unresponsive and timed out
AK-8000-DG 2 1579289.1 The appliance mgmt interface unresponsive and the appliance had to be rebooted
AK-8000-H7 2 1491956.1 "The JBOD '' is configured incorrectly" is reported
AK-8000-H7 2 1542500.1 Mismatched SIM Firmware (FW)
AK-8000-H7 2 1579300.1 A ZFS Appliance disk is configured incorrectly
AK-8001-79 2    
AK-8001-F7 2    
AK-8001-GU 2 1456741.1 Service Processor has stopped responding to requests
AK-8001-GU 2 1579302.1 The service processor has stopped responding to requests
AK-8001-U1 2 1579303.1 A cluster peer state error has been detected
AK-8001-W7 3 1579304.1 The cluster peer has failed and reset
AK-8002-RU 3    
AK-8003-UG 2 1579305.1 Fibre Channel connectivity has been lost on one or more ports
AK-8003-W9 3 1579306.1 Multiple transient Fibre Channel state changes on a port
AK-8003-Y6 3 1553287.1 The device configuration is invalid.
AK-8004-08 2 1564538.1 Incompatible drives installed
AK-8004-1M 2 1545768.1 A power supply is installed in the incorrect slot
AK-8004-27 3 1546894.1 Configuration mismatch of Logzilla drive types
AK-8004-3U 2 1545785.1 EBOD not fully populated; Unsupported partially populated DE2-24P
AMD-8000-1W 2 1021122.1 Memory module errors exceeding acceptable levels
AMD-8000-2F 2 1021123.1 Memory module correctable errors exceeding acceptable levels
AMD-8000-3K 2 1021124.1 Memory module correctable errors exceeding acceptable levels
AMD-8000-48 2 1021125.1 Multibit memory module errors
AMD-8000-5M 2 1021127.1 CPU errors exceeded acceptable levels
AMD-8000-67 2 1021128.1 CPU errors exceeded acceptable levels
AMD-8000-7U 2 1021129.1 CPU errors exceeded acceptable levels
AMD-8000-8L 2 1021130.1 CPU errors exceeded acceptable levels
AMD-8000-9G 2 1021131.1 CPU errors exceeded acceptable levels
AMD-8000-AV 2 1021132.1 CPU errors exceeded acceptable levels
AMD-8000-C0 2 1021133.1 CPU errors exceeded acceptable levels
AMD-8000-DT 2 1021134.1 CPU errors exceeded acceptable levels
AMD-8000-E6 2 1021135.1 CPU errors exceeded acceptable levels
AMD-8000-FN 2 1021136.1 CPU errors exceeded acceptable levels
AMD-8000-G9 2 1021137.1 CPU errors exceeded acceptable levels
AMD-8000-HK 2 1021138.1 CPU errors exceeded acceptable levels
AMD-8000-JF 2 1021139.1 CPU errors exceeded acceptable levels
AMD-8000-KW 2 1021140.1 A Fault In A DRAM Channel
AMD-8000-L1 2 1021190.1 Memory Module Has Failed BIOS Test
AMD-8000-MU 2 1021191.1 Errors from a single page exceeding acceptable levels
AMD-8000-N7 2 1021192.1 Errors from a single page exceeding acceptable levels
AMD-8000-PM 2 1021193.1 Errors from a single page exceeding acceptable levels
DISK-8000-0X 2 1021141.1 Predictive Disk Failure Imminent
DISK-8000-12 2 1021142.1 Disk Temperature Exceeded Threshold
DISK-8000-2J 2 1021143.1 Disk Self-Test Failure
DISK-8000-3E 3 1021144.1 A non-recoverable hardware failure was detected by the device while performing a command       
DISK-8000-4Q 3 1021145.1 SCSI fault for media: terminated with a non-recovered error condition
DISK-8000-D5 2 1427614.1 There have been excessive transient ZFS checksum errors on this disk.
DISK-8000-6R 3 1382747.1 A path to the device has been unconfigured due to transport instability
DISK-8000-74 2 1427579.1 There has been a non-recovered medium read error
DISK-8000-8D 2 1427593.1 There has been a non-recovered medium write error
FMD-8000-0W 2 1021146.1 Solaris Fault Manager Received Unexpected Event
FMD-8000-11 2 1021147.1 Solaris Fault Manager unable to determine message summary
FMD-8000-2K 2 1021148.1 Solaris Fault Manager component had disabling error
FMD-8000-3F 2 1021149.1 Solaris Fault Manager component has erroneous configuration file
GMCA-8000-21 3 1021154.1 Level 0 CPU Cache Fault
GMCA-8000-47 3 1021156.1 Level 2 CPU Cache Fault
GMCA-8000-5U 3 1021157.1 CPU Cache Fault
GMCA-8000-MM 3 1021201.1 Level 2 Data Cache Fault
GMCA-8000-N8 3 1021206.1 Data Cache Fault
GMCA-8000-SL 3 1021215.1 Instruction Cache Fault
GMCA-8000-UV 3 1021235.1 Memory fault
GMCA-8000-YN 3 1021245.1 Memory module correctable errors exceeding acceptable levels
MPT-8000-0S 2 1115005.1 Remediation of PCI Express 8-Port Host Adapter (Pandora) B3 cards with C0 cards.
NAS-8000-5H 2    
NXGE-8000-0U 2 1021161.1 NXGE XFP Optical Transceiver Fault
NXGE-8000-17 2 1021162.1 XAUI Fault
PCIEX-8000-0A 2 1021223.1 PCIEX subsystem problem
PCIEX-8000-1P 2 1021224.1 PCIEX subsystem problem
PCIEX-8000-25 2 1021225.1 PCIEX subsystem problem
PCIEX-8000-3S 2 1022184.1 PCIEX subsystem problem
PCIEX-8000-43 2 1021305.1 PCIEX subsystem problem
PCIEX-8000-5Y 2 1021306.1 PCIEX subsystem problem
PCIEX-8000-6D 2 1021307.1 PCIEX subsystem problem
PCIEX-8000-7H 2 1021309.1 PCIEX subsystem problem
PCIEX-8000-8R 2 1021310.1 PCIEX subsystem problem
PCIEX-8000-94 2 1021312.1 PCIEX subsystem problem
PCIEX-8000-AQ 2 1021313.1 PCIEX subsystem problem
PCIEX-8000-CC 2 1021314.1 PCIEX subsystem problem
PCIEX-8000-DJ 2 1021316.1 PCIEX subsystem problem
PCIEX-8000-EE 2 1021317.1 PCIEX subsystem problem
PCIEX-8000-FX 2 1021320.1 PCIEX subsystem problem
PCIEX-8000-G2 2 1021321.1 PCIEX subsystem problem
PCIEX-8000-HS 2 1022183.1 PCIEX subsystem problem
SENSOR-8000-1N 3 1257154.1 Power supply failed
SENSOR-8000-26 3 1262238.1 Fan failed
SENSOR-8000-3T 3 1262178.1 Power supply failed
SENSOR-8000-7L 3 1262258.1 External condition causing power supply failure
SENSOR-8000-8U 2    
SENSOR-8000-AM    2    
SUNOS-8000-20 2 1021440.1 SUNOS subsystem or controlling software problem
SUNOS-8000-3V 2 1021442.1 PCI subsystem problem
SUNOS-8000-46 2 1021443.1 PCI subsystem or its controlling software problem
SUNOS-8000-5T 2 1021444.1 PCI bus or controlling software problem
SUNOS-8000-69 2 1021452.1 PCI controller problem
SUNOS-8000-7N 2 1021461.1 PCI bus problem
SUNOS-8000-8W 2 1021462.1 PCI controller software problem
ZFS-8000-D3 3 1021617.1 ZFS device failure
ZFS-8000-FD 3 1021619.1 Too many I/O errors on ZFS device
ZFS-8000-GH 2 1021621.1 Too many checksum errors on ZFS device
ZFS-8000-HC 3 1021622.1 ZFS pool I/O failures
ZFS-8000-K4 3 1021625.1 ZFS intent log read failure
ZFS-8000-QJ 3 1480040.1 Missing data on ZFS device. Applications are unaffected if sufficient replicas exist

 

 

See also Oracle ASR Fault Coverage for Storage Products: ZFS  (https://docs.oracle.com/cd/E37710_01/doc.41/e56166/toc.htm)

 

 

 

***Checked for relevance on 30-MAY-2018***

References

https://stbeehive.oracle.com/content/dav/st/Global%20Disk%20Automation/Public%20Documents/Unified_Storage/zfssa_alarm_path.html
<NOTE:1173733.1> - PSH Procedural Article for Solaris FMA-Based Diagnosis
https://docs.oracle.com/cd/E23824_01/html/821-1451/glgki.html

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback