Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2113439.1
Update Date:2018-05-30
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2113439.1 :   Oracle ZFS Storage Appliance: Relative Performance of DRAM, HDDs, Readzillas and Logzillas (March 2016)  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Purpose
Scope
Details


Applies to:

Sun ZFS Storage 7420 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
Oracle ZFS Storage ZS3-BA - Version All Versions and later
Oracle ZFS Storage ZS4-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Purpose

To provide information regarding the relative performance of the Physical Memory DRAM (DIMMs), Hard Disk Drives (HDDs), Readzillas (Read-Accelerated SSDs) and Logzillas (Write-Accelerated SSDs) used in the Series 7000 Unified Storage Systems, Sun ZFS Storage 7x20 Series and the Oracle ZFS Storage ZS3-x/ZS4-x Appliances.

This information is correct as of 1st March 2016.

Scope

Information is provided for the benefit of all RPE/TSC and Field Engineers supporting the Oracle NAS product set.

 

Details

 

 Device    IOPs      Write Bandwidth  Read Bandwidth  Read Latency   Access Density
DRAM (any config)  > 300K ~20,000 MB/sec  ~20,000 MB/sec        120us     > 250.000
 18G logzilla     3000      120 MB/sec             n/a          n/a           n/a
 73G logzilla (gen3)     7000      200 MB/sec             n/a          n/a           n/a
 73G logzilla (gen4)  11000      350 MB/sec             n/a          n/a           n/a
 200G logzilla  33000      510 MB/sec             n/a          n/a           n/a
 500G readzilla    2500    << 30 MB/sec      40 MB/sec      1300us           5.0
 1.6TB readzilla (Sandisk)     21000      100 MB/sec    200 MB/sec        900us         15.2
 1.6TB readzilla (HGST)  51000      140 MB/sec    420 MB/sec        560us         31.9
 3TB 7K HDD      120      175 MB/sec    175 MB/sec      8600us        0.042
 4TB 7K HDD      120      180 MB/sec    180 MB/sec      8600us        0.029
 8TB 7K HDD      120      200 MB/sec    200 MB/sec      8600us        0.015
 300G 15K HDD      250      170 MB/sec    170 MB/sec      4300us        0.795
 300G 10K HDD      160      165 MB/sec    170 MB/sec      6250us        0.531
 900G 10K HDD      160      170 MB/sec    170 MB/sec      6250us        0.177

 

 

 

***Checked for relevance on 30-MAY-2018***