Asset ID: |
1-79-2113439.1 |
Update Date: | 2018-05-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2113439.1
:
Oracle ZFS Storage Appliance: Relative Performance of DRAM, HDDs, Readzillas and Logzillas (March 2016)
Related Items |
- Sun ZFS Storage 7420
- Oracle ZFS Storage ZS3-2
- Sun Storage 7110 Unified Storage System
- Oracle ZFS Storage ZS4-4
- Sun Storage 7210 Unified Storage System
- Sun Storage 7410 Unified Storage System
- Oracle ZFS Storage ZS3-4
- Sun Storage 7310 Unified Storage System
- Sun ZFS Storage 7120
- Oracle ZFS Storage Appliance Racked System ZS4-4
- Sun ZFS Storage 7320
- Oracle ZFS Storage ZS3-BA
|
Related Categories |
- PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
|
In this Document
Applies to:
Sun ZFS Storage 7420 - Version All Versions and later
Oracle ZFS Storage ZS3-2 - Version All Versions and later
Oracle ZFS Storage ZS3-4 - Version All Versions and later
Oracle ZFS Storage ZS3-BA - Version All Versions and later
Oracle ZFS Storage ZS4-4 - Version All Versions and later
7000 Appliance OS (Fishworks)
Purpose
To provide information regarding the relative performance of the Physical Memory DRAM (DIMMs), Hard Disk Drives (HDDs), Readzillas (Read-Accelerated SSDs) and Logzillas (Write-Accelerated SSDs) used in the Series 7000 Unified Storage Systems, Sun ZFS Storage 7x20 Series and the Oracle ZFS Storage ZS3-x/ZS4-x Appliances.
This information is correct as of 1st March 2016.
Scope
Information is provided for the benefit of all RPE/TSC and Field Engineers supporting the Oracle NAS product set.
Details
Device |
IOPs |
Write Bandwidth |
Read Bandwidth |
Read Latency |
Access Density |
DRAM (any config) |
> 300K |
~20,000 MB/sec |
~20,000 MB/sec |
120us |
> 250.000 |
18G logzilla |
3000 |
120 MB/sec |
n/a |
n/a |
n/a |
73G logzilla (gen3) |
7000 |
200 MB/sec |
n/a |
n/a |
n/a |
73G logzilla (gen4) |
11000 |
350 MB/sec |
n/a |
n/a |
n/a |
200G logzilla |
33000 |
510 MB/sec |
n/a |
n/a |
n/a |
500G readzilla |
2500 |
<< 30 MB/sec |
40 MB/sec |
1300us |
5.0 |
1.6TB readzilla (Sandisk) |
21000 |
100 MB/sec |
200 MB/sec |
900us |
15.2 |
1.6TB readzilla (HGST) |
51000 |
140 MB/sec |
420 MB/sec |
560us |
31.9 |
3TB 7K HDD |
120 |
175 MB/sec |
175 MB/sec |
8600us |
0.042 |
4TB 7K HDD |
120 |
180 MB/sec |
180 MB/sec |
8600us |
0.029 |
8TB 7K HDD |
120 |
200 MB/sec |
200 MB/sec |
8600us |
0.015 |
300G 15K HDD |
250 |
170 MB/sec |
170 MB/sec |
4300us |
0.795 |
300G 10K HDD |
160 |
165 MB/sec |
170 MB/sec |
6250us |
0.531 |
900G 10K HDD |
160 |
170 MB/sec |
170 MB/sec |
6250us |
0.177 |
***Checked for relevance on 30-MAY-2018***