Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2095090.1
Update Date:2018-02-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2095090.1 :   FS System: Drive Firmware Matrix for the FS1-2  


Related Items
  • Oracle FS1-2 Flash Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Flash Storage>SN-EStor: FSx
  •  




In this Document
Purpose
Scope
Details


Applies to:

Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Purpose

 To provide an up to date matrix of the Drive firmware versions available for the FS1-2.

Scope

This document is a quick reference table to show the dependencies between software versions, drive firmware versions and the drive hardware for the FS1-2 Storage System.  It is intended for customers as well as Oracle service and support personnel.

Details

The matrix below provides the details on drive firmware versions.  Media Type indicates whether the drive is HDD (Hard Disk Drive) or SSD (Solid State Drive).  Capacity and Model columns are self-explanatory.  The Drive Type (GUI) column shows how this drive will appear in the Oracle FS System Manager GUI Software and Firmware display from the Support tab.  The Minimum Supported Release is the FS1-2 software version in which a drive firmware version was first introduced.  The FS1-2 Release History shows the Releases where new drive firmware versions were released.  Unless otherwise noted, those same versions will be carried forward in future releases.

 

FS1-2 Drive Firmware Matrix
Media Type
Capacity
Model Drive Type (GUI) Initial Release Release History
Firmware Version
HDD 300GB   H109030SESUN300G  

Hitachi 300GB HDD

R6.0.0 R6.2.0 A720
R6.1.0 A690
R6.0.0 A600
900GB   H109090SESUN900G  

Hitachi 900GB HDD

R6.0.0 R6.2.0 A720
R6.1.0 A690
R6.0.0 A600
1.2TB H1T1812SFSUN1.2T HGST Cobra-F 1.2TB FIPS HDD R6.2.0 R6.2.4 D990
R6.2.0 D770
H1018124FSUN1.2T HGST Cobra-F 1.2TB EAEU R6.2.16 R6.2.16 C99H
4TB   H7240AS60SUN4.0T   Hitachi 4TB HDD R6.0.0 R6.2.4 A3A0
R6.1.1 A2D2
R6.1.0 A260
R6.0.0 A1CA
8TB H7280A520SUN8.0T HGST AriesHC 8TB (non-FIPS) HDD R6.2.0 R6.2.15 PD51
R6.2.14 P9E2
R6.2.123 PAG1
R6.2.82 P9E2
R6.2.2 P901
R6.2.0 P554
H7280A525SUN8.0T HGST AriesHC 8TB FIPS HDD R6.2.0 R6.2.15 4D51
R6.2.14 49E2
R6.2.123 4AG1
R6.2.82 49E2
R6.2.4 455B1
R6.2.0 455B
H7289B524SUN8.0T HGST Libra 8TB EAEU R6.2.16 R6.2.16 C376
10TB H7210A520SUN010T HGST Libra 10TB Standard HDD R6.2.14 R6.2.14 A374
H7210A521SUN010T

HGST Libra 10TB   TCG HDD

R6.2.14 R6.2.14 B374
H7210A524SUN10T

HGST Libra 10TB EAEU

R6.2.16 R6.2.16 C376
SSD 400GB LB406M SUN400G SanDisk 400GB SSD R6.0.0 R6.2.82 S318
R6.0.0 S311
HSCAC2DA4SUN400G Sunset Cove Plus 400GB SSD R6.1.1 R6.2.0 A29A
R6.1.1 A122
HSFAC2DA4SUN400G Sunset Cover Plus 400GB FIPS SSD R6.2.0 R6.2.4 D29E1
R6.2.0 D29E
1.6TB LB1606R SUN1.6T SanDisk 1600GB SSD R6.0.0 R6.2.82 S318
R6.0.0 S311
HSCAC2DA2SUN1.6T Sunset Cove Plus 1600GB SSD R6.1.1 R6.2.0 A29A
R6.1.1 A122
HSFAC2DA2SUN1.6T HGST Sunset Cove Plus 1.6TB FIPS SSD R6.2.0 R6.2.4 D29E1
R6.2.0 D29E
3.2TB HBCAC2DH2SUN3.2T Hitachi Bear Cove 3.2TB Non-FIPS SSD R6.2.14 R6.2.16 A122
R6.2.14 A087
HBTAC2DH2SUN3.2T HGST Bear Cove 3.2TB TCG SSD R6.2.14 R6.2.16 B122
R6.2.14 B087
HBSAC2DH2SUN3.2T HGST Bear Cove 3.2TB EAEU R6.2.16 R6.2.16 C122

1 Package name change only - Drive firmware is unchanged.

2 R6.2.8 was a controlled release.  This firmware is available in R6.2.9.

3 R6.2.12 and R6.2.13 are controlled releases - do NOT install these drive firmware versions.  These versions will be removed in the R6.2.14 release.

NOTE: Keeping the drive firmware version up to date is critical.  As of R6.2.4 drive replacements as well as adding new Drive Enclosures may fail if the latest versions are not installed on the FS1-2 Pilots.

 

There are two methods to determine the current version of Drive Firmware in your FS1-2:

Oracle FS System Manager (GUI):

  1. From the System tab, expand Hardware and then select Drive Enclosures.
  2. Right click on the Drive Enclosure you wish to examine and then select "View".
  3. One by one click on the the individual drives in that Drive Enclosure noting the Firmware Number on the right:

    Drive Firmware

  4. Repeat for other Drive Enclosures as needed.

Command Line (fscli):

C:>fscli login -u administrator -oracleFs <shared_ip_of_FS1>
Password:

Login Successful
*****************************************************
**                                                 **
** This is a company computer system with access   **
** restricted to those with proper authorization.  **
** Authorized parties are restricted to those      **
** functions which have been assigned to perform   **
** work related duties. Any unauthorized access    **
** will be investigated and prosecuted to the      **
** full extent of the law. If you are not an       **
** authorized user, disconnect now.                **
**                                                 **
*****************************************************
C:\>fscli enclosure -list
/ENCLOSURE-01
/ENCLOSURE-02
/ENCLOSURE-03
C:\>fscli enclosure -list -enclosure /ENCLOSURE-01 -details
/ENCLOSURE-01
    Id                       : 5080020001474E7B
    DisplayNumber            : 1
    Comment                  :
    HardwareComponentStatus  : NORMAL
    OverallFruStatus         : NORMAL
    TemperatureStatus        : NORMAL
    SerialNumber             : 1307FM4006
...
    DiskDrive
        DriveStatus          : NORMAL
        Model                : H109030SESUN300G <============== Drive Model
        SerialNumber         : 1242CSCSDDF
        FirmwareVersion      : A720             <============== Drive firmware version
        DriveSlot            : 0
        StorageClass         : perfdisk
        EncryptionSupported  : false
        Capacity Gigabytes   : 304.7
        Bytes                : 304685419480
...
C:\>fscli enclosure -list -enclosure /ENCLOSURE-02 -details
/ENCLOSURE-02
...
C:\>fscli enclosure -list -enclosure /ENCLOSURE-03 -details
/ENCLOSURE-03
...

 

NOTE: at this time ALL Drive Firmware upgrades require an outage.

 