![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2095090.1 : FS System: Drive Firmware Matrix for the FS1-2
In this Document
Applies to:Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. PurposeTo provide an up to date matrix of the Drive firmware versions available for the FS1-2. ScopeThis document is a quick reference table to show the dependencies between software versions, drive firmware versions and the drive hardware for the FS1-2 Storage System. It is intended for customers as well as Oracle service and support personnel. DetailsThe matrix below provides the details on drive firmware versions. Media Type indicates whether the drive is HDD (Hard Disk Drive) or SSD (Solid State Drive). Capacity and Model columns are self-explanatory. The Drive Type (GUI) column shows how this drive will appear in the Oracle FS System Manager GUI Software and Firmware display from the Support tab. The Minimum Supported Release is the FS1-2 software version in which a drive firmware version was first introduced. The FS1-2 Release History shows the Releases where new drive firmware versions were released. Unless otherwise noted, those same versions will be carried forward in future releases.
1 Package name change only - Drive firmware is unchanged. 2 R6.2.8 was a controlled release. This firmware is available in R6.2.9. 3 R6.2.12 and R6.2.13 are controlled releases - do NOT install these drive firmware versions. These versions will be removed in the R6.2.14 release. NOTE: Keeping the drive firmware version up to date is critical. As of R6.2.4 drive replacements as well as adding new Drive Enclosures may fail if the latest versions are not installed on the FS1-2 Pilots.
There are two methods to determine the current version of Drive Firmware in your FS1-2: Oracle FS System Manager (GUI):
Command Line (fscli): C:>fscli login -u administrator -oracleFs <shared_ip_of_FS1>
Password: Login Successful ***************************************************** ** ** ** This is a company computer system with access ** ** restricted to those with proper authorization. ** ** Authorized parties are restricted to those ** ** functions which have been assigned to perform ** ** work related duties. Any unauthorized access ** ** will be investigated and prosecuted to the ** ** full extent of the law. If you are not an ** ** authorized user, disconnect now. ** ** ** ***************************************************** C:\>fscli enclosure -list /ENCLOSURE-01 /ENCLOSURE-02 /ENCLOSURE-03 C:\>fscli enclosure -list -enclosure /ENCLOSURE-01 -details /ENCLOSURE-01 Id : 5080020001474E7B DisplayNumber : 1 Comment : HardwareComponentStatus : NORMAL OverallFruStatus : NORMAL TemperatureStatus : NORMAL SerialNumber : 1307FM4006 ... DiskDrive DriveStatus : NORMAL Model : H109030SESUN300G <============== Drive Model SerialNumber : 1242CSCSDDF FirmwareVersion : A720 <============== Drive firmware version DriveSlot : 0 StorageClass : perfdisk EncryptionSupported : false Capacity Gigabytes : 304.7 Bytes : 304685419480 ... C:\>fscli enclosure -list -enclosure /ENCLOSURE-02 -details /ENCLOSURE-02 ... C:\>fscli enclosure -list -enclosure /ENCLOSURE-03 -details /ENCLOSURE-03 ...
NOTE: at this time ALL Drive Firmware upgrades require an outage.
Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|