![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2093675.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.4 (Solaris - Physical) for January 2016
In this Document
Applies to:Oracle Exalogic Elastic Cloud Software - Version 2.0.4.0.0 to 2.0.6.2.4Oracle Exalogic Elastic Cloud X2-2 Hardware Exalogic Elastic Cloud X3-2 Hardware Exalogic Elastic Cloud X4-2 Hardware Exalogic Elastic Cloud X5-2 Hardware Oracle Solaris on x86-64 (64-bit) PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around January 2016 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNote: This PSU includes updates to ELLC 14.2.5
Patch Download
Released: January 2016 Product Version: 2.0.6.2.4 (on X2-2/X3-2/X4-2/X5-2) for Oracle Solaris x86-64 PATCH 22136605 - EXALOGIC SOLARIS 2.0.6.2.4 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR JANUARY 2016 Patch Readme DocumentationRefer to the readme documentation attached 22136605-Solaris.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 22136605-Solaris.zip:
INTERNAL Pre-requisites PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racks Refer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Document ID : 2093677.1 - Exalogic Infrastructure January 2016 PSU - Fixed Bugs List. Appendix B: Patching Known IssuesCheckHWnFWProfile fails on X5-2 Solaris.Symptoms On Physical Solaris X5-2 systems /opt/exalogic.tools/tools/CheckHWnFWProfile fails with:- ******************************************************************************************************************* Does not contain supported disk controller. Required LSI MR9261-8i. But has LSI ******************************************************************************************************************* Cause This is due to a known issue that is tracked through the following bug: BUG 20745068 - CHECKHWNFWPROFILE FAILS POST COMPUTE NODE UPGRADE TO APR15 PSU ON X5-2
There are two underlying issues that cause CheckHWnFWProfile to fail on Solaris X5-2 systems: 1. The supported configuration metadata is incorrect and contains an incorrect reference to the LSI MR9261-8i disk controller. The profile check against the actual version installed on the node (LSI MR9361-8i) fails. The supported version is LSI MR9361-8i; this error may be safely ignored 2. The MegaCli utility that is installed on X5-2 nodes is unable to detect the disk controller to obtain/upgrade/downgrade the installed firmware version. You may safely continue to use the node with the version of the disk controller firmware shipped from the factory. Solution/Workaround This error may be safely ignored and you may safely continue to use the node with the version of the disk controller firmware shipped from the factory.
Upgrade from EECS 2.0.4.0.4 and earlier releases (containing NM2 FW v2.0.x) to EECS 2.0.4.0.5 and newer releases (containing NM2 FW v2.1.x) requires downtime to perform the switch FW upgrade.Symptoms Following the NM2 gateway switch firmware upgrade, all Exalogic compute nodes running Solaris experience an outage of any EoIB networks configured on the nodes. Cause This is a known issue for NM2 switch firmware upgrades from v2.0.x to v2.1.x, which results in a change of the EoIB network interface names on the compute nodes. Solution/Workaround The solution is already provided in the README for the Exalogic Solaris PSUs. For further details please review <Note 1571367.1>
Post Patching Switches, NFS mount point is in hung stateSymptoms: # svcadm restart network/physical:default
ZFS patching fails due to losing IO access to the pool.Symptoms: ZFS patching fails and Exapatch terminated as follows ... INFO: ZFS-Storage-Head xx.xx.xx.xx successfully completed all pre-patch Observed in the exapatch log, errors are similar to the following:- Head in Active state, continuing...
Cause: el01sn01:configuration storage> get pool = exalogic status = exported owner = el01sn01 el01sn01:> configuration cluster show Properties: state = AKCS_OWNER << Active head doesn't own the pool description = Active (takeover completed) peer_asn = 2058f7ae-0247-c86e-c2f1-94f8cd68faa7 peer_hostname = el01sn02 peer_state = AKCS_STRIPPED peer_description = Ready (waiting for failback) Children: resources => Configure resources Node el01sn02 was READY (PASSIVE) but the storage was online on this. el01sn02:configuration storage> get << this is the passive head pool = exalogic status = online errors = 0 owner = el01sn01 profile = mirror log_profile = log_stripe cache_profile = cache_stripe scrub = resilver completed after 0h0m with 0 errors
As the result, all clients are losing IO access to the pool.
Reboot the active head and retry the patching Refer <Note 1910623.1>
psuSetup.sh failing due to lack of free space.Symptoms: psusetup.sh fails due to lack of free space. It fails while reserving share quota to 200M for exalogic-lctools. [root@compute-node]# ./psuSetup.sh <zfs_ip> INFO: xx.xx.xx.xxx is a ZFS appliance @ INFO: using existing "common" on the ZFS Appliance with IP address
Cause: Free up space in ZFSA. Refer <Note 2039102.1> _______________________________________________________________________________________________________________________________________________________________________________________ PCIE fault HW alert in ZFS post IB firmware updateSymptoms: PCIE related HW fault is reported in ZFS, after applying IB card firmware. Error message is Similar to:- SUNW-MSG-ID: SPX86-8003-QH, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Mon Aug 17 06:34:36 2015 PLATFORM: i86pc, CSN: 1441NML0FE, HOSTNAME: denp04sn02 SOURCE: appliance/kit/akd:default, REV: 1.0 EVENT-ID: d63362ca-89ea-e1e9-90cb-ee2bc152e335 DESC: An Integrated I/O (II0) non-fatal error in downstream PCIE device has occurred. AUTO-RESPONSE: The service-required LED on the chassis will be illuminated. IMPACT: System continues to run with degraded resources. REC-ACTION: Contact your service provider for proper repair procedures. Cause: A Hermon IB card firmware upgrade was active on the card. Solution/Workaround: Implement the workaround mentioned in <Note 2040757.1> _____________________________________________________________________________________________________________________________________________________________________________________ Exalogic X2-2 Compute Nodes ILOM Network Settings Lost After PSU UpgradeRefer to <Note 2114516.1> for details on this known issue. _____________________________________________________________________________________________________________________________________________________________________________________ Exalogic: ZFS-7320 ILOM Network Settings Lost on X2-2 and X3-2 Racks After PSU UpgradeRefer to <Note 2115679.1> for details on this known issue.
Appendix C: FAQsInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingRefer to below Note <Note 1997466.1>: Information About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic Patching
References<NOTE:1997466.1> - Information About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic Patching<NOTE:2040757.1> - Oracle ZFS Storage Appliance: How To Resolve - An Integrated I/O non-fatal error in downstream PCIE device has occurred. <NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note <NOTE:2087741.1> - Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks <NOTE:1449226.1> - Exachk Health-Check Tool for Exalogic <NOTE:2114516.1> - Exalogic X2-2 Compute Nodes ILOM Network Settings Lost After PSU Upgrade <NOTE:2115679.1> - Exalogic: ZFS-7320 ILOM Network Settings Lost on X2-2 and X3-2 Racks After PSU Upgrade <NOTE:1329262.1> - How to Perform a Healthcheck on Exalogic Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||
|