Solution Type  Predictive Self-Healing Sure

Solution  2078933.1 :   FMM-8000-FX - Compute node activation policy mismatch  


Related Items
  • Netra Modular System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Netra Modular System
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: FMM-8000-FX

Details

Compute node activation policy mismatch.

Type

Fault

fault.frame.computenode.activation.policy.mismatch

Severity

Major

Description

The compute node activation policy has encountered some mismatch.

A mismatch can be due to the following reasons;

-Policy definition for the compute node has activation disabled.
-Wrong system type.
-Wrong memory size.
-Wrong F/W version.
-Point-to-point failure.
-Optical patch panel mismatch.
-FMM determines insufficient power to activate node.

Examine the underlying ereports to determine why the mismatch occurred.

Automated Response

None.

Impact

The fault monitoring module was unable to activate compute node.

Suggested Action for System Administrator

Verify the policy definition for the compute node has enabled activation.

Contact Oracle support services.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)