Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2078918.1
Update Date:2017-01-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2078918.1 :   FMM-8000-DJ - Compute node discovery failure  


Related Items
  • Netra Modular System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Netra Modular System
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: FMM-8000-DJ

Details

Compute node discovery failure

Type

Fault

fault.frame.computenode.discovery.failed

Severity

Major

Description

The compute node frame discovery failed.

Frame discovery may fail due to a checksum or hang issue.

1. boot progress checksum is bad.
Frame monitoring module reads frame backplane node (FBN) area and determines checksum is bad.

2. boot progress is hung.
Frame monitoring module did not receive anything from RMS.

Verify the latest ILOM/BIOS firmware verison is installed on the compute node.

If not the latest, please remove the compute node from the rack and update ILOM image.

 

Automated Response

None.

Impact

The frame monitoring module is unable to configure compute node.

Suggested Action for System Administrator

Verify the policy definition for the compute node has enabled deactivation.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback