Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2078890.1
Update Date:2017-01-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2078890.1 :   FMM-8000-AQ - Compute node communication lost  


Related Items
  • Netra Modular System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Netra Modular System
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: FMM-8000-AQ

Details

Compute node communication lost

Type

Fault

fault.frame.computenode.communication-lost

Severity

Major

Description

The frame monitoring module (FMM) lost heartbeat communications between a compute node.

The frame monitoring module (FMM) lost hearbeat to the compute node.

The loss of heartbeat can be due to a link failure.

1. Check the switch ports on the fault monitoring module.
2. Check cable connection between the FMM and the frame backplane module (FBN).

 

Automated Response

None.

Impact

The frame monitoring module has lost ability to monitor the compute node.

Suggested Action for System Administrator

Verify switch ports on fault monitoring module and cable connections between the frame monitoring module (FMM) and the frame backplane node (FBN) are correct.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.