![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2078890.1 : FMM-8000-AQ - Compute node communication lost
In this Document
Applies to:Netra Modular SystemInformation in this document applies to any platform. PurposeProvide additional information for message ID: FMM-8000-AQ DetailsCompute node communication lost Type Fault fault.frame.computenode.communication-lost Severity Major Description The frame monitoring module (FMM) lost heartbeat communications between a compute node. The frame monitoring module (FMM) lost hearbeat to the compute node. The loss of heartbeat can be due to a link failure. 1. Check the switch ports on the fault monitoring module.
Automated Response None. Impact The frame monitoring module has lost ability to monitor the compute node. Suggested Action for System Administrator Verify switch ports on fault monitoring module and cable connections between the frame monitoring module (FMM) and the frame backplane node (FBN) are correct. Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||
|