Purpose

 Provide additional information for message ID: FMM-8000-5Y

Details

 Invalid Frame hardware configuration

Type

Fault

fault.frame.invalid-hw-configuration

Severity

Major

Description

The frame monitoring module has determined a problem exists with the cable harness.

Location known by frame monitoring module (FMM) doesn't match the
physical location of the frame backplane module (FBN) in the rack.

This fault will only occur when a cable harness is incorrectly wired
between the frame monitoring module (FMM) and frame backplane node (FBN).

Result will be loss of frame management monitoring of compute nodes due to incorrect addressing.

Verify the cable harness connections between the frame monitoring module (FMM) and frame backplane nodes (FBN) are correct.

 

Automated Response

Frame level service-required LED is illuminated.

Impact

Loss of frame management monitoring of compute nodes.

Suggested Action for System Administrator

Contact Oracle Support Services.