![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2078644.1 : FMM-8000-3S - Missing FBN
In this Document
Applies to:Netra Modular SystemInformation in this document applies to any platform. PurposeProvide additional information for message ID: FMM-8000-3S DetailsMissing FBN Type Fault fault.frame.backplane-node.absent Severity Major Description The frame monitoring module has discovered that a frame backplane node is missing. Number of supported FBNs are defined in the frame configuration image. Actual number of FBNs physically present should match this number Automated Response Frame level service-required LED is illuminated. Impact The frame is unable to support the number of compute nodes currently configured. Suggested Action for System Administrator Install the missing frame backplane node as soon as possible. Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||
|