![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2077331.1 : ETHSWITCH-8000-C2 - SEFOS process failure.
In this Document
Applies to:Oracle Switch ES1-24Information in this document applies to any platform. PurposeProvide additional information for message ID: ETHSWITCH-8000-C2 Scope
DetailsSEFOS process failure. Type Fault Severity Critical Description The SEFOS process has crashed repeatedly and has been disabled. Manually restart the /SYS/sefos target. SEFOS will restart with a default configuration. You should apply and save any custom configuration again. Note that the old configuration file is still available and can be recovered; it is stored as switch.conf.crash. Since the file most likely caused the repeated crashes you should proceed with extreme caution if you attempt to recover it. Automated Response Switch operation is shut down. Impact Switch management is disabled, and the switch will not forward traffic. Suggested Action for System Administrator Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments This solution has no attachment |
||||||||||||||||||
|