Purpose
Additional Information for Message ID: SPT-8002-4D
Details
Type
- Hardware Fault
fault.chassis.voltage.failing-nc
-
Severity
- Critical
Description
A voltage reading on a board has been measured outside the threshold for a second time.
Automated Response
The system will be powered cycled.
-
Impact
The system will be powered cycled. No service is required.
-
Suggested Action for System Administrator
Event lists and/or ereports for both the temperature and voltage thresholds will not report or take any action on the upper or lower non-critical temperature thresholds, as the system will not have a chance to poll when this alarm is asserted.
By default, it takes approximately 5 seconds for sensor polling. In order to poll 3 readings: upper non-critical, upper critical and upper non-recoverable thresholds, it would take more than 30 seconds.
Please refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
References
<BUG:24717350> - SYSFW: VERY HIGH SENSOR READINGS ARE STILL REPORTED AS NON-CRITICAL EREPORTS