![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 2057607.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.3 (Linux - Virtual) for October 2015
In this Document
Applies to:Exalogic Elastic Cloud X5-2 HardwareOracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 to 2.0.6.2.3 Oracle Exalogic Elastic Cloud X2-2 Hardware Exalogic Elastic Cloud X3-2 Hardware Exalogic Elastic Cloud X4-2 Hardware Linux x86-64 Oracle Virtual Server(x86-64) PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around October 2015 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsNote:
Patch Download
Released: October 2015 Product Version: 2.0.6.2.3 (on X2-2/X3-2/X4-2/X5-2) for Oracle Exalogic Elastic Cloud infrastructure PATCH 21445837 - EXALOGIC VIRTUAL 2.0.6.2.3 (on X2-2/X3-2/X4-2/X5-2) PATCH SET UPDATE (PSU) FOR October 2015 Patch Readme DocumentationRefer to the readme documentation attached 21445837-Virtual.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 21445837-Virtual.zip: 21445837-Virtual Pre-requisitesO2CB Cluster TimeoutBefore patching, verify that the cluster heartbeat timeout is set correctly, as documented in the Document ID : 1995593.1 - Increase O2CB Cluster Heartbeat Timeout on Exalogic Virtual PCIe Renumbering check on ZS3-ES storage heads in Exalogic x4-2 and x5-2 racksRefer to following Note which has information on this important pre-requisite check. <Note 2087741.1>: Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks
AppendicesAppendix A: Fixed Bugs ListPlease review Doc ID 2057633.1: Exalogic Infrastructure October 2015 PSU – Fixed Bugs List Appendix B: Patching Known IssuesThe pre-requisite step to update Weblogic Server configuration properties for non-default passwords prior to upgrading Exalogic Control Services failsSymptoms A pre-requisite step is included in section entitled "1.1 Prerequisites" to configure Weblogic Server prior to upgrading Exalogic Control Services to handle non-default passwords configured for the weblogic user. Running the command as documented results in an error as shown below: [oracle@elctrl ~]$ /u01/app/oracle/ovm-manager-3/weblogic/wlconfig.sh weblogic <non-default-password>
-bash: /u01/app/oracle/ovm-manager-3/weblogic/wlconfig.sh: Permission denied Invoking it using sh as follows runs into ClassNotFoundException, as shown in the sample below: [oracle@elctrl ~]$ sh /u01/app/oracle/ovm-manager-3/weblogic/wlconfig.sh weblogic welcome1
Exception in thread "main" java.lang.NoClassDefFoundError: weblogic.WLST at gnu.java.lang.MainThread.run(libgcj.so.7rh) Caused by: java.lang.ClassNotFoundException: weblogic.WLST not found in gnu.gcj.runtime.SystemClassLoader{urls=[file:./], parent=gnu.gcj.runtime.ExtensionClassLoader{urls=[], parent=null}} at java.net.URLClassLoader.findClass(libgcj.so.7rh) at java.lang.ClassLoader.loadClass(libgcj.so.7rh) at java.lang.ClassLoader.loadClass(libgcj.so.7rh) at gnu.java.lang.MainThread.run(libgcj.so.7rh) [oracle@elctrl ~] Cause A step to set the WLS environment variables is missing in the documentation. Also, the wlconfig.sh script is not executable; it needs to be invoked using "sh". Solution/Workaround
Exapasswd: EMOC sync fails for Exapasswd with special characters.Symptoms If exapasswd is used with certain special characters synchronization with EMOC would fail. Observed following error messages:
Error while synchronizing passwords with Ops Center
Cause The issue is with following special characters: 1) ` (acute or back quote) 2) : (colon) 3) ; (semi-colon)
Solution/Workaround It is known limitation that exapasswd does not support quotes (double/single) also. And it has already been documented. These new findings will also be updated in the Expasswd user's guide accordingly. Many oclib (/var/mnt/virtlibs/*) Mounts Seen On EMOC Control VServer.Refer to <Note 2053733.1> for information on this known issue.ZFS Upgrade Failed. Storage node ilom console indicates error in joining cluster.Symptoms While applying the July 2015 PSU on X5-2 rack, the upgrade of ZS3-ES may fail. The exapatch fails with:- "ERROR: Could not ssh to ZFS host xx.xx.xx.xx after upgrade. " Further, When I see the storage node ilom of the failed head, it is stuck at this stage : Oracle ZFS Storage ZS3-ES Configuration
Copyright (c) 2008, 2015, Oracle and/or its affiliates. All rights reserved. NET-0 <=> NET-1 <=> NET-2 <=> NET-3 <X> SUNW-MSG-ID: AK-8000-2U, TYPE: Defect, VER: 1, SEVERITY: Major EVENT-TIME: Tue Jun 2 17:01:26 UTC 2015 PLATFORM: i86pc, CSN: 1427NML0E5, HOSTNAME: scat01sn02 SOURCE: aktty, REV: 1.0 EVENT-ID: 1fc05eee-db80-e94d-d6c2-c06714389111 DESC: The appliance experienced an unrecoverable protocol error while attempting to join a cluster of appliances. Refer to http://sun.com/msg/AK-8000-2U for more information. AUTO-RESPONSE: No automated response is possible for this defect. IMPACT: The appliance cannot be configured into the cluster. REC-ACTION: Reboot the system and attempt to configure the cluster again. Contact your vendor for support. ESC-3: Halt ESC-4: Reboot ESC-5: Info For help, see http://www.oracle.com/goto/ZS3-ES/docs/
Cause
@ Details of this issue are in this MOS note:
@ . @ Oracle ZFS Storage Appliance: ZS3-X Clustron Card in PCIE Slot 2 Does Not @ Initialize During boot. (Doc ID 1910623.1) @ . @ The following bug is referenced from the MOS note: @ . @ BUG 18672251 - AK-8000-2U: unrecoverable protocol error on the ZS3-ES @ (X4170M3) appliance
Solution/Workaround Manually reboot the storage head with ESC-4. Refer to <Note 1910623.1> ___________________________________________________________________________________________________________________________________________________________________________________
PCIE fault HW alert in ZFS post IB firmware updateSymptoms: PCIE related HW fault is reported in ZFS, after applying IB card firmware. Error message is Similar to:- SUNW-MSG-ID: SPX86-8003-QH, TYPE: Fault, VER: 1, SEVERITY: Major
EVENT-TIME: Mon Aug 17 06:34:36 2015 PLATFORM: i86pc, CSN: 1441NML0FE, HOSTNAME: denp04sn02 SOURCE: appliance/kit/akd:default, REV: 1.0 EVENT-ID: d63362ca-89ea-e1e9-90cb-ee2bc152e335 DESC: An Integrated I/O (II0) non-fatal error in downstream PCIE device has occurred. AUTO-RESPONSE: The service-required LED on the chassis will be illuminated. IMPACT: System continues to run with degraded resources. REC-ACTION: Contact your service provider for proper repair procedures. Cause: A Hermon IB card firmware upgrade was active on the card. Solution/Workaround: Workaround is mentioned in Mos <Note 2040757.1> PSU Upgrade fails while upgrading ZFSSA.Symptoms: The ZFSSA upgrade will fail when applying the appliance from 2011 version of the software to the 2013 version of the software. Exapatch terminated as follows .....
INFO: ZFS-Storage-Head xx.xx.xx.x2 is active ZFS head. INFO: ZFS-Storage-Head xx.xx.xx.x1 is ready ZFS head. INFO: ZFS-Storage-Head xx.xx.xx.x1 running pre-patch checks for ready head INFO: ZFS-Storage-Head xx.xx.xx.x1 Ready head checks completed. INFO: ZFS-Storage-Head xx.xx.xx.x1 successfully completed all pre-patch checks ERROR: ZFS-Storage-Head xx.xx.xx.x2 STOP!! There are 4 active problem(s) on this head, Please resolve them first, Exiting Unable to proceed as pre-patch checks failed for active head xx.xx.xx.x2 Additional information may be found in the console output and the log file: /var/log/exapatch_20150818205629.log Errors are similar to the following:
problem-000 2015-4-5 02:51:11 Major Fault ZFS device 'id1,sd@SATA_____TOSHIBA_THNSNC51________XXXXXXXXXXXX/a' in pool 'exalogic' failed. Major Fault Never
problem-001 2015-4-5 02:51:11 Major Fault ZFS device 'id1,sd@SATA_____TOSHIBA_THNSNC51________XXXXXXXXXXXX/a' in pool 'exalogic' failed. Major Fault Never problem-002 2015-4-5 02:51:11 Major Fault ZFS device 'id1,sd@SATA_____TOSHIBA_THNSNC51________XXXXXXXXXXXX/a' in pool 'exalogic' failed. Major Fault Never problem-003 2015-4-5 02:51:11 Major Fault ZFS device 'id1,sd@SATA_____TOSHIBA_THNSNC51________XXXXXXXXXXXX/a' in pool 'exalogic' failed. Major Fault Never Cause: The ZFSSA upgrade will fail when applying the Oct 2015 PSU due to bug 19024367 with the ZFSSA. This is a known issue that can happen when upgrading from the 2011 version of the software to the 2013 version of the software. After the head that has been upgraded becomes active, it tries to access the readzilla on the passive head. The readzillas are local to head each head and one head cannot access the readzilla of its peer. Typically the active head is supposed to ignore the readzilla disks on its peer, but due to bug 19024367, these disks are marked as failed on the active head. The passive head will not show any failed disks. To validate this compare the serial numbers of the disks marked as failed with the serial numbers of the readzilla disks on its peer. This is a false positive and can be safely ignored. Solution/Workaround: Since Exapatch does not allow you to proceed, the software on the of the Note: After the manual update if still the issue exist, reboot the storage head.
Guest vServer update fails during yum update of rpms with 'up2dateErrors'Refer to Exalogic PSU Known Issues <Note 1571367.1>, section "Guest vServer update fails during yum update of rpms with 'up2dateErrors'" for information on this known issue. Exapatch console output message has ' WARNING: unable to update patch history: '.Symptoms While running the Exapatch command, the console output has following warning message:-
WARNING: unable to update patch history: Unable to find unique identifier "1352NML06M" for Compute-Node xx.xx.xx.xx in the rack history file.
Cause This is an expected behavior when the rack history file is not created beforehand and does not affect the node functionality.Solution To avoid this, prior to patching a rack history should be created:[root@compute-node]# /exalgic-lctools/bin/exapatch -a refreshHistory
______________________________________________________________________________________________________________________________________________________________________
Exalogic Compute Node or Guest vServer PSU Upgrade Using Exapatch Fails With Error "IndexError: list index out of range"Refer to <Note 2092033.1> for details on this known issue. _____________________________________________________________________________________________________________________________________________________________________________________ Exalogic X2-2 Compute Nodes ILOM Network Settings Lost After PSU UpgradeRefer to <Note 2114516.1> for details on this known issue. Appendix C: Errata1. Migration of assets managed by Proxy ControllersIn the troubleshooting MOS note section "Problem: components are listed under both the ProxyControllers(PC)"Original Text In the Exalogic Control BUI, if it is observed that any of the component asset is listed under both the Proxy Controllers (PC), they need to be migrated to a single PC. Updated Text For a given switch (NM2-GW switches, NM2-36p switch), only one proxy controller needs to be managing it. If a particular switch appears to be managed by both PC1 and PC2, it must be migrated to one of the proxy controllers. It does not matter whether it is migrated to PC1 or PC2. One or more compute nodes may appear in the Managed Assets list of both proxy controllers. For instance, el01cn01.example.com may appear as being managed by both PC1 and PC2. This is expected behavior; no migration is required for the compute nodes. Other non-switch assets, such as ZFS storage heads and PDU may also appear in the Managed Assets list of both proxy controllers. Migration is not required for these assets prior to applying the July 2015 PSU; migration is required only for switches. Login to EMOC BUI and navigate to "Administration" item in the left panel and find the entries for 'PC1' and 'PC2' vServers. Select a Proxy Controller say, "PC1" in the left panel. In the center panel click on the "Managed Assets" tab and set the Asset Type Filter to "Network Switches" to get list of switches managed by the 'PC1' Proxy Controller. Select the switch that you wish to migrate to the other ProxyController "PC2". Click on the icon that provides the option to "Migrate Assets". A confirmation dialog shows up, select 'Migrate' button to proceed. Once the migration completes finishes, a notification pop-up appears at the bottom right corner of the EMOC BUI, confirming the successful migration. ______________________________________________________________________________________________________________________________________________________________ Appendix D: FAQsInformation About Usage Of Exapatch Force ( -f or --force ) Option Used During Exalogic PatchingRefer to <Note 1997466.1> for details Guest vServer patching FAQ'sRefer to <Note 2031749.1> for details.
References<NOTE:2092033.1> - Exalogic Compute Node or Guest vServer PSU Upgrade Using Exapatch Fails With Error "IndexError: list index out of range"<NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues <NOTE:2114516.1> - Exalogic X2-2 Compute Nodes ILOM Network Settings Lost After PSU Upgrade <NOTE:1530781.1> - Exalogic Infrastructure Physical and Virtual Releases/PSUs – Software and Firmware Version Information <NOTE:2053733.1> - Many oclib (/var/mnt/virtlibs/*) Mounts Seen On EMOC Control VServer After Upgrading To Exalogic April 2015 PSU 2.0.6.2.1 Or Later Versions <NOTE:2016700.1> - Exalogic: vServer Creation Takes a Long Time or Fails After a Few Days of Uptime <NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note <NOTE:1329262.1> - How to Perform a Healthcheck on Exalogic <NOTE:1995236.1> - Exalogic Patch Set Update (PSU) Release 2.0.6.2.1 (Linux - Virtual) for April 2015 <NOTE:1449226.1> - Exachk Health-Check Tool for Exalogic <NOTE:2087741.1> - Patching ZS3-ES Renumbering Check On Exalogic x4-2 And x5-2 Racks Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|