Solution Type  Predictive Self-Healing Sure

Solution  2028263.1 :   FMD-8000-CV - A FRU Has Been Removed  


Related Items
  • SPARC T8-1
  •  
  • SPARC T3-1B
  •  
  • SPARC SuperCluster T4-4 Full Rack
  •  
  • SPARC T8-4
  •  
  • SPARC T3-4
  •  
  • SPARC T7-4
  •  
  • Netra SPARC T4-1 Server
  •  
  • Solaris Operating System
  •  
  • Solaris Cluster
  •  
  • SPARC T4-2
  •  
  • SPARC SuperCluster T4-4
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • SPARC T3-2
  •  
  • SPARC T4-1
  •  
  • Solaris (SPARC)
  •  
  • SPARC T7-1
  •  
  • SPARC T3-1
  •  
  • Netra SPARC T4-1B
  •  
  • SPARC T4-4
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Solaris Operating System
Solaris Cluster
Solaris (SPARC)
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.

Purpose

 Provide additional information for message ID: FMD-8000-CV

Details

Type: Alert

   alert.oracle.solaris.fmd.fru-monitor.fru-remove

Severity: Minor 

Description:

The FRU identified in the message content and fmadm output has either been replaced or removed from the product. This may be the result of repair or system reconfiguration action.

The FRU Status field  in the fmadm output will provide an indication of whether it was replaced or removed:

Status                    : Active/not present  -> The FRU previously present at the indicated Location has been removed

Status                     :  replaced -> The FRU at the indicated Location has been replaced with another

Automated Response:

FMD topology has been updated to reflect this change.

Impact:

If the FRU was removed, the impact will vary depending the FRU and the associated hardware resources located on that FRU.

There should be no impact if the FRU was replaced with the same type of FRU and the associated resources have been returned to operation.

Suggested Action for System Adminitrators:

None.

This event is essentially informational in nature and does not indicate a fault or problem in the product that requires any specific administrative or service action to be taken in response.

Refer to the following document for the latest procedures for displaying event content:

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID: 1173733.1)

 

NOTE: This message ID will not result in a service request being automatically submitted by ASR.

 

References

<BUG:22286820> - SUPPRESS FRU-ADD/REMOVE ALERTS ON PCIEXDEV NODES ON SPARC SYSTEMS