Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2021618.1
Update Date:2018-03-27
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2021618.1 :   How to identify Infiniband HCA cards on Oracle SuperCluster  


Related Items
  • SPARC SuperCluster T4-4 Full Rack
  •  
  • Oracle SuperCluster M6-32 Hardware
  •  
  • Oracle SuperCluster T5-8 Hardware
  •  
  • Solaris Operating System
  •  
  • SPARC SuperCluster T4-4
  •  
  • Oracle SuperCluster T5-8 Half Rack
  •  
  • SPARC SuperCluster T4-4 Half Rack
  •  
  • Oracle SuperCluster T5-8 Full Rack
  •  
  • Oracle SuperCluster Specific Software
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
  •  




In this Document
Purpose
Scope
Details
References


Applies to:

Oracle SuperCluster M6-32 Hardware
Oracle SuperCluster T5-8 Full Rack
Oracle SuperCluster T5-8 Hardware
Oracle SuperCluster T5-8 Half Rack
Oracle SuperCluster Specific Software
Oracle Solaris on SPARC (64-bit)

Purpose

This document helps you identify the type of Infiniband Host Channel Adapters (HCA) installed in a SuperCluster and the firmware versions they're running.

Scope

This document is for SuperCluster administrators and Oracle support personnel. Minimum technical expertise is needed to follow the advice in this document. This advice is limited to identifying only Infiniband HCAs on SuperCluster, it does not extend to other I/O cards, devices or other platforms.

Details

These steps should be performed as the root user and repeated on every domain (LDom) on the SuperCluster.

If the domain is running Solaris 11, then you will be using the command /usr/sbin/fwflash, from the package system/firmware-utilities. This package is delivered as part of the Solaris 11 core operating system.

If the domain is running Solaris 10, then you will be using the command /usr/sbin/firmwareflash, from the package SUNWfirmwareflash. If your Solaris 10 domain is missing this package, it is delivered for Solaris SPARC in MOS patch 18064232.

Run the command:

# fwflash -c IB -l

or

# firmwareflash -c IB -l


These commands will list details for each Infiniband HCA installed in this domain. Note the "Product" and "Firmware revision" for each device and compare to the following table:

 

ProductDescriptionChipsetSupported SuperCluster PlatformsLatest Firmware Version Certified On SuperCluster 1Firmware Patch NumberProduct Documentation Library
375-3697-01 Sun InfiniBand Dual Port 4x QDR PCIe ExpressModule Host Channel Adapter M2 CX2 - M2
SPARC SuperCluster T4-4 2.11.2010 16340042 http://docs.oracle.com/cd/E19157-01/index.html
375-3696-01 Sun InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 CX2 - M2
Oracle SuperCluster T5-8 and M6-32 2.11.2012 19445097 http://docs.oracle.com/cd/E19241-01/index.html
7046442 Oracle Dual Port QDR Infiniband Adapter Low Profile M3 CX3 - M3
Oracle SuperCluster T5-8, M6-32 and M7
2.11.1280 17549486 http://docs.oracle.com/cd/E40985_01/index.html

 

1 The latest firmware version certified on SuperCluster is not necessarily the latest firmware version available for the platform. Refer to the document Oracle SuperCluster Supported Software Versions - All Hardware Types (Doc ID 1567979.1) for the latest details on supported firmware versions.