Asset ID: |
1-79-2021618.1 |
Update Date: | 2018-03-27 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2021618.1
:
How to identify Infiniband HCA cards on Oracle SuperCluster
Related Items |
- SPARC SuperCluster T4-4 Full Rack
- Oracle SuperCluster M6-32 Hardware
- Oracle SuperCluster T5-8 Hardware
- Solaris Operating System
- SPARC SuperCluster T4-4
- Oracle SuperCluster T5-8 Half Rack
- SPARC SuperCluster T4-4 Half Rack
- Oracle SuperCluster T5-8 Full Rack
- Oracle SuperCluster Specific Software
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>SPARC SuperCluster>DB: SuperCluster_EST
|
In this Document
Applies to:
Oracle SuperCluster M6-32 Hardware
Oracle SuperCluster T5-8 Full Rack
Oracle SuperCluster T5-8 Hardware
Oracle SuperCluster T5-8 Half Rack
Oracle SuperCluster Specific Software
Oracle Solaris on SPARC (64-bit)
Purpose
This document helps you identify the type of Infiniband Host Channel Adapters (HCA) installed in a SuperCluster and the firmware versions they're running.
Scope
This document is for SuperCluster administrators and Oracle support personnel. Minimum technical expertise is needed to follow the advice in this document. This advice is limited to identifying only Infiniband HCAs on SuperCluster, it does not extend to other I/O cards, devices or other platforms.
Details
These steps should be performed as the root user and repeated on every domain (LDom) on the SuperCluster.
If the domain is running Solaris 11, then you will be using the command /usr/sbin/fwflash, from the package system/firmware-utilities. This package is delivered as part of the Solaris 11 core operating system.
If the domain is running Solaris 10, then you will be using the command /usr/sbin/firmwareflash, from the package SUNWfirmwareflash. If your Solaris 10 domain is missing this package, it is delivered for Solaris SPARC in MOS patch 18064232.
Run the command:
# fwflash -c IB -l
or
# firmwareflash -c IB -l
These commands will list details for each Infiniband HCA installed in this domain. Note the "Product" and "Firmware revision" for each device and compare to the following table:
Product | Description | Chipset | Supported SuperCluster Platforms | Latest Firmware Version Certified On SuperCluster 1 | Firmware Patch Number | Product Documentation Library |
375-3697-01 |
Sun InfiniBand Dual Port 4x QDR PCIe ExpressModule Host Channel Adapter M2 |
CX2 - M2
|
SPARC SuperCluster T4-4 |
2.11.2010 |
16340042 |
http://docs.oracle.com/cd/E19157-01/index.html |
375-3696-01 |
Sun InfiniBand Dual Port 4x QDR PCIe Low Profile Host Channel Adapter M2 |
CX2 - M2
|
Oracle SuperCluster T5-8 and M6-32 |
2.11.2012 |
19445097 |
http://docs.oracle.com/cd/E19241-01/index.html |
7046442 |
Oracle Dual Port QDR Infiniband Adapter Low Profile M3 |
CX3 - M3
|
Oracle SuperCluster T5-8, M6-32 and M7
|
2.11.1280 |
17549486 |
http://docs.oracle.com/cd/E40985_01/index.html |
1 The latest firmware version certified on SuperCluster is not necessarily the latest firmware version available for the platform. Refer to the document Oracle SuperCluster Supported Software Versions - All Hardware Types (Doc ID 1567979.1) for the latest details on supported firmware versions.
References
<NOTE:1567979.1> - Oracle SuperCluster Supported Software Versions - All Hardware Types
Attachments
This solution has no attachment