Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2010329.1
Update Date:2017-09-21
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2010329.1 :   SPT-8002-3P - fault.chassis.device.fpga  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • Solaris (SPARC)
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Solaris (SPARC)
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Oracle Solaris on SPARC (64-bit)
Oracle Solaris on SPARC (32-bit)

Purpose

 Additional Information for message ID: SPT-8002-3P

Details

Type: Hardware Fault     
      Fault
      fault.chassis.device.fpga

 Severity
      Critical

  Description 
      A device has failed.

 Automated Response 
     The service required LED on the chassis will be illuminated.

 Impact
     There is no immediate impact, however this fault may cause other problems to occur.

 Suggested Action for System Administrator
     Refer to the following document for the latest procedures regarding this diagnosis.
 PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.