Purpose
Additional Information for Message ID: SPSUN4V-8002-9P
Details
Type: Hardware Fault
Fault
fault.memory.dq fault.memory.multidimm
Severity:
Major
Description
The number of correctable errors associated with several memory modules have exceeded acceptable levels.
Automated Response
An attempt will be made to remove the affected memory from service.
Impact
The DIMMs may be deconfigured at system restart which would reduce total system memory capacity.
Suggested Action for System Administrator
Use 'fmadm faulty' to provide a more detailed view of this event.
Please refer to the associated reference document for the latest service procedures and policies regarding this diagnosis.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)