Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2010319.1
Update Date:2017-09-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2010319.1 :   SPSUN4V-8002-A5 - fault.memory.dq-ss fault.memory.multidimm  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC M8-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M7-8
  •  
  • SPARC T4-2
  •  
  • Oracle MiniCluster Specific Software
  •  
  • SPARC T8-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC T7-2
SPARC T4-2
Oracle SuperCluster M7 Hardware
SPARC M7-8
SPARC M7-16
SPARC

Purpose

Additional Information for Message ID: SPSUN4V-8002-A5

Details

Type: Hardware Fault
     Fault         
     fault.memory.dq-ss fault.memory.multidimm

Severity:
    
Major

Description
    
The number of correctable errors associated with several memory modules have exceeded acceptable levels.

Automated Response
       An attempt will be made to remove the affected memory from service.

Impact
       The DIMM may be deconfigured at system restart which would reduce total system memory capacity.

Suggested Action for System Administrator
      Use 'fmadm faulty' to provide a more detailed view of this event.
      Please refer to the associated reference document for the latest service procedures and policies regarding this diagnosis.   
     
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback