Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-2010317.1
Update Date:2017-09-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  2010317.1 :   SPSUN4V-8002-D3 - fault.memory.dimm-ue fault.memory.multidimm  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • SPARC M7-8
  •  
  • SPARC T4-2
  •  
  • SPARC T8-2
  •  
  • Oracle MiniCluster Specific Software
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Oracle MiniCluster Specific Software
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC

Purpose

Additional Information for Message ID: SPSUN4V-8002-D3

Scope

Details

Type: Hardware Fault
     Fault

     fault.memory.dimm-ue fault.memory.multidimm

  

Severity:
     Major

Description
    
Uncorrectable errors have occurred while accessing memory.

 

Automated Response
     An attempt will be made to remove the affected memory from service. 

    Host HW may restart.

 

Impact

     Total system memory capacity has been reduced and some applications may have been terminated.

     The DIMM may be deconfigured at system restart which would reduce total system memory capacity.

Suggested Action for System Administrator
      Use 'fmadm faulty' to provide a more detailed view of this event.
      Please refer to the associated reference document for the latest service procedures and policies regarding this diagnosis.   
      PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback