Asset ID: |
1-79-2010300.1 |
Update Date: | 2016-01-05 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2010300.1
:
SPT-8002-1S - fault.chassis.config.psu.fail
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- Oracle MiniCluster Specific Software
- SPARC T7-2
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Oracle MiniCluster
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC
Purpose
Additional Information for message ID: SPT-8002-1S
Details
Type: Hardware Fault
Fault
fault.chassis.config.psu.fail
Severity
Critical
Description
An unsupported power supply has been detected.
Automated Response
The system will continue to operate if redundant power is present.
The chassis wide service-required LED is illuminated.
If present, the PSU service-required LED is illuminated.
Impact
The system will exhibit loss of redundant power.
Suggested Action for System Administrator
Refer to the following document for the latest procedures regarding this diagnosis.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment