Asset ID: |
1-79-2010149.1 |
Update Date: | 2017-09-20 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
2010149.1
:
SPSUN4V-8002-GH - A range of memory locations associated with a DRAM row address has generated uncorrectable errors.
Related Items |
- SPARC T8-1
- SPARC T8-4
- Oracle SuperCluster M7 Hardware
- SPARC M7-8
- SPARC T7-4
- SPARC M8-8
- SPARC S7-2L
- Oracle MiniCluster Specific Software
- SPARC S7-2
- SPARC T8-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Oracle SuperCluster M7 Hardware
Oracle MiniCluster Specific Software
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC
Purpose
Additional Information for message ID: SPSUN4V-8002-GH
Details
Type: Hardware Fault
Fault
fault.memory.multidimm fault.memory.row-ue
Severity
Major
Description
A range of memory locations associated with a DRAM row address has generated uncorrectable errors.
Automated Response
An attempt will be made to remove the affected memory from service.
Impact
The DIMM may be deconfigured at system restart which would reduce total system memory capacity.
Suggested Action for System Administrator
Use 'fmadm faulty' to provide a more detailed view of this event.
Please refer to the associated reference document for the latest service procedures and policies regarding this diagnosis.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment