![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1991454.1 : Oracle ZFS Storage Appliance: Interoperability for 2013.1.3.0 Software Release
In this Document
Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions and laterOracle ZFS Storage ZS3-BA - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later Oracle ZFS Storage ZS4-4 - Version All Versions and later 7000 Appliance OS (Fishworks) PurposeThis document provides interoperability matrices for Oracle ZFS Storage Appliance Software version 2013.1.3.0 based on three client connection types: Ethernet, Fibre Channel, and InfiniBand. This software release supports the following platforms: Oracle ZFS Storage ZS4-4, Oracle ZFS Storage ZS3-4, Oracle ZFS Storage ZS3-2, Oracle ZFS Storage ZS3-BA, Sun ZFS Storage 7420, Sun ZFS Storage 7320, Sun ZFS Storage 7120. DetailsInteroperability for Ethernet Client ConnectionsConnectivity OptionsDirect connect and switch attach connectivity are supported unless noted otherwise. Supported Ethernet Switches and NICsAll 1Gb/s switches, 10Gb/s switches, and NICs from vendors who follow standard specifications are supported. Protocol Support for Ethernet Connected ClientsThe following operating systems and architectures are supported over NFSv3, NFSv4, iSCSI, SMB, FTP, SFTP, FTPS, HTTP, and HTTPS. Key for Versions
Supported Oracle Database dNFS and ASM Key Features for Ethernet Client ConnectionsThe following table lists Oracle Database dNFS and ASM key features that were tested for compatibility with Ethernet client connections. Key for Versions
Interoperability for Fibre Channel Client ConnectionsConnectivity OptionsFibre Channel (FC) Point-to-Point (FC-P2P), switch attach (FC-SW), and 4GB and 8GB arbitrated loop (FC-AL) connectivity is supported unless noted otherwise. Supported FC Switches and HBAsThe following FC switches and HBAs are supported with standard configurations:
Support for FC SAN BootBooting from a storage area network (SAN) offers many benefits, leading to cost savings as well as higher levels of protection, ease of management, increased flexibility, and reduced downtime. To configure the appliance and client server for an FC SAN boot, see document Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. Configuring FC Client MultipathingTo configure FC client multipathing, see document Oracle ZFS Storage Appliance: How to set up Client Multipathing (Doc ID 1628999.1). Protocol Support for FC Connected ClientsThe following FC configurations are supported unless noted otherwise. Key for Versions
Supported Oracle Database ASM Key Features for FC Client ConnectionsThe following table lists Oracle Database ASM key features that were tested for compatibility with FC client connections. All HBAs, drivers, and ALUA are consistent with the previous table. Key for Versions
Interoperability for InfiniBand Client ConnectionsSupported InfiniBand Switches and HCAsAll 40Gb (QDR) configured Mellanox switches and HCAs are supported. No additional vendor switches or HCAs are supported at this time. Protocol Support for InfiniBand Connected ClientsThe following InfiniBand (IPoIB) configurations are supported unless noted otherwise. Supported protocols include NFSv3, NFSv4, iSCSI, SMB, FTP, FTPS, SFTP, HTTP, and HTTPS. Key for Versions
Supported Oracle Database dNFS Key Features for InfiniBand Client ConnectionsThe following table lists Oracle Database dNFS key features that were tested for compatibility with InfiniBand (IPoIB) client connections. Key for Versions
RDMA Support for InfiniBand Client ConnectionsThe following table lists remote direct memory access (RDMA) support for InfiniBand (IPoIB) client connections. Supported protocols include NFSv3, NFSv4, and iSER. Key for Versions
Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|