Asset ID: |
1-79-1988694.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1988694.1
:
ILOM-8000-D8 - FRUID access problem
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- SPARC M7-8
- SPARC T8-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC T7-4
SPARC
Purpose
Additional Information for Message ID: ILOM-8000-D8
Details
Type
- Hardware Fault
- fault.fruid.inaccessible
Severity
- Critical
Description
-
A Field Replaceable Unit (FRU) FRUID SEEPROM cannot be accessed.
Automated Response
-
The service-required LED may be illuminated on the affected FRU and chassis.
Impact
-
The system may not be able to use one or more components on the affected FRU. This may prevent the system from powering on.
Suggested Action for System Administrator
- The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment