Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1985614.1 :   Oracle EXALOGIC Current Product Issues X5-2 / X6-2  


Related Items
  • Exalogic Elastic Cloud X5-2 Eighth Rack
  •  
  • Exalogic Elastic Cloud X5-2 Hardware
  •  
  • Exalogic Elastic Cloud X5-2 Quarter Rack
  •  
  • Exalogic Elastic Cloud X5-2 Full Rack
  •  
  • Exalogic Elastic Cloud X5-2 Half Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: EXALOGIC
  •  




Oracle Confidential PARTNER - Available to partners (SUN).
Reason: distro

Applies to:

Exalogic Elastic Cloud X5-2 Hardware
Exalogic Elastic Cloud X5-2 Full Rack
Exalogic Elastic Cloud X5-2 Half Rack
Exalogic Elastic Cloud X5-2 Eighth Rack
Exalogic Elastic Cloud X5-2 Quarter Rack
Information in this document applies to any platform.

Purpose

This document contains the EXALOGIC X5-2 /X6-2 Product Issues.

Details

Documentation    Overview    Patches/Firmware (X2-2,X3-2,X4-2) Patches/Firmware (X5-2) Patches/Firmwares (X6-2)  Product Issues (X2-2,X3-2,X4-2)  Product Issues (X5-2,X6-2)  Training/Knowledge    SSH   X86 Home

 

X5-2 Hardware Issues:

IssueIssue
Number
StatusDocumentCR/SRResolutionUpdated

The first 20 racks or so of Exalogic X5 shipped with uprev firmware on the Aspen RAID card.
This may cause an error when running checkhwnfwprofile on the compute nodes.
This can be igrnored as the card works properly with either firmware version

 1  OPEN     The mismatch error can be ignored as the Aspen RAID Card will function properly with either firmware on board.             
The list of serial numbers will be attached to this issue when they are available.
The First few racks [20] have shipped with:  FW Package = 24.3.0-0073 
New orders as of March 1, 2015 will ship with:  FW Package = 24.3.0-0063

 March 1, 2015

 

  X5-2 and X5-2L front disk backplanes lose all disks         2  OPEN   21916073  If you're seeing this issue the drives will be invisible to the RAID HBA. Ongoing review.  Feb 10 2016

Exachk reports failed raid batteries within Solaris due to missing MegaCli and StorCli

Status on eldc01elcn01:
FAIL => RAID battery level is low.
DATA FROM ELDC01ELCN01 - RAID BATTERY LEVEL
# OS Type : SunOS
# /opt/MegaRAID/MegaCli -AdpBbuCmd -a0 #
ERROR:Could not detect controller.
Failed to get ControllerId List.
Failed to get CpController object.
Exit Code: 0x01
/opt/MegaRAID/MegaCli command failed.

 

 3  Open    20745068

 Engineerng is looking into adding the storcli .pkg in the next PSU release.

 

Workaround;

How to download and install the management SW and tool for 8-Port 12Gbps SAS-3 RAID HBA (Aspen-INT) (Doc ID 2106540.1)

 

After installing the storcli .pkg, you can check the raid battery status with the following:

/opt/MegaRAID/CLI/storcli /c0/cv show all

 

Update 7/11/2016 - Storcli package is now included with

                             2.0.6.2.160719 EL PSU

 

 

 May, 2016

X86 and X5 Engineered Systems (X5-2 or X5-2L) may see 8-slot disk backplane failures.

 4 Open    

May see all disks or a few disks offline, for full details see KM note 2097145.1

 

 

X5-2 Software Issues:

IssueIssue
Number
StatusDocumentCR/SRResolutionUpdated
 ZFS ILOM SP console with "shell: Maximum number of sessions exhausted" error - EMOC version 12.1.4.2507  1  CLOSED  

 22022422

21383988

 Upgrade to 2016_Jan_PSU  2/19/2016
Lots of systems seeing SPX86A-8004-TG and SPX86A-8002-RK FMA faults with no clear failure cause.

 

 

 

 

2

OPEN  

21647754

22709532

22665076

ASR team logged this bug due to many many cases being opened for these two fault codes, with no clear indicator of which component is bad, if any. This bug was logged to dig deeper to find out what is going on.

If you have a case with either of these errors (SPX86A-8004-TG or SPX86A-8002-RK) logged, please attach to the bug and upload the snapshot for analysis of what the true fault is. Engineers need to upload the snapshots so we can properly diagnose these cases going forward. Just clearing the fault and ignoring is not the correct course of action, nor guessing at the cause and replacing random parts.

If there are any questions please contact Mick Tabor.

Engineering is working on FMA diagnostic reporting enhancements under bug #22709532. Until enhancements are released continue to attach to bug #21647754 for assistance.

 

 

 

 

1/4/2017

 

X6-2 Hardware Issues:

 Issue  Issue #  Status        
             

 

X6-2 Software Issues:

             
             

 

 

 

 

References

<NOTE:1360006.1> - Oracle Exalogic Product Page X2-2 , X3-2, X4-2, X5-2, X6-2 (2017)
<NOTE:1360024.1> - Exalogic Knowledge
<NOTE:1432636.1> - Sun EXALOGIC X2-2 , X3-2 , X4-2 Current Product Patches & Firmware
<NOTE:1330254.1> - X86 Product Home
<NOTE:1360304.1> - Exalogic Documentation
<NOTE:1360008.1> - Exalogic Training

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback