![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1959616.1 : Exalogic Patch Set Update (PSU) Release 2.0.6.2.0 (Linux - Physical) for January 2015
In this Document
Applies to:Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 to X2 [Release X2]Exalogic Elastic Cloud X4-2 Hardware - Version X4 to X4 [Release X4] Exalogic Elastic Cloud X3-2 Hardware - Version X3 to X3 [Release X3] Oracle Exalogic Elastic Cloud Software - Version 2.0.0.0.0 to 2.0.6.1.2 Linux x86-64 PurposeOracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware software like WebLogic server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and InfiniBand networking. The purpose of this document is to provide specific information around January 2015 Patch Set Update (PSU) for that system. ScopeThe target audience of this document are engineers and system administrators who plan to apply the Exalogic PSU. This document provides the following:
This document will be kept up-to-date with updates to errata and known issues. DetailsPatch Download
Released: January 2015 Product Version: 2.0.6.2.0 (on X2-2/X3-2/x4-2) for Oracle Linux x86-64 PATCH 19370014 - EXALOGIC LINUX 2.0.6.2.0 (on X2-2/X3-2/x4-2) PATCH SET UPDATE (PSU) FOR January 2015
Patch Readme DocumentationRefer to the readme documentation attached 19370014-Linux.zip to this Document on how to upgrade the Exalogic infrastructure:
The readme content structure layout of the 19370014-Linux.zip: 19370014-Linux AppendicesAppendix A: Fixed Bugs ListPlease review Document ID : 1959625.1 - Exalogic Infrastructure January 2015 PSU - Fixed Bugs List. Appendix B: Patching Known IssuesUpgrading NM2 Switch Firmware on full rack Exalogic systems or multi-rack Exa systems causing Network outage
Note: The issue does not occur when Exalogic racks (one eighth, quarter, half ) are connected to Exadata racks. Symptoms Cause The NM2 Port ID space has increased four times from firmware version 2.0 to 2.1. Therefore, port ID collisions may occur if NM2 switches with firmware version 2.0 and 2.1 are run on the same fabric. This issue can cause network outages on the InfiniBand fiber. Solution/Workaround In order to prevent this issue, manipulation of the switch 'GWInstance' value may be required to ensure unique port IDs are generated by performing the following steps: # showgwconfig
Note the GWInstance "Running Value" on each of the switches. 1. Ensure that all the GWInstance values are even numbers [root@nm2gw-ib01 ~]# setgwinstance 16
Stopping Bridge Manager.. [ OK ] Starting Bridge Manager. [ OK ] root@nm2gw-ib01 ~]# For example, if the GWInstance values of four NM2 switches are 10, 20, 30 & 40, it will be necessary to change the GWInstance value of 10 to 16. ZFS Upgrade fails due to pre-patch check failure on ReadzillasFor information on this known issue refer to Exalogic Infrastructure PSU Upgrade Known Issues <Note 1571367.1>, section "ZFS Upgrade fails while applying Jan 2015 PSU due to pre-patch check failure on Readzillas". References<NOTE:1571367.1> - Exalogic Infrastructure PSU Upgrade - Known Issues<NOTE:1449226.1> - Exachk Health-Check Tool for Exalogic <NOTE:1329262.1> - How to Perform a Healthcheck on Exalogic <NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||
|