Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1951684.1
Update Date:2016-01-05
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1951684.1 :   SPSUN4V-8002-72 - DRAM bit stuck.  


Related Items
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M7-8
  •  
  • Oracle MiniCluster Specific Software
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




Applies to:

Oracle SuperCluster M7 Hardware
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC

Purpose

Provide additional information for message ID:  SPSUN4V-8002-72.

Details

Predictive Self-Healing Article
SPSUN4V-8002-72 - DRAM bit stuck.

Type
Fault
fault.memory.dram-ss-spare

Severity
Major

Description
A fatal error occurred while trying to allocate and/or deploy spare memory.

Message ID:SPSUN4V-8002-72  indicates that the Fault Management System has received an error report indicating a memory DRAM bit is stuck resulting in an fault being asserted.

Automated Response
There will be no notification.

Impact
System performance may be minimally reduced. 

Suggested Action for System Administrator
This is a non-serviceable fault, and no action should be taken.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.