Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1949907.1
Update Date:2018-01-03
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1949907.1 :   FS System: Standard Storage Profiles for FS1-2 Release 6.1.3 and Higher  


Related Items
  • Oracle FS1-2 Flash Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Flash Storage>SN-EStor: FSx
  •  


Standard Storage Profiles for Release 6.1.x of the Oracle FS-1 Storage System

Applies to:

Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Purpose

This document provides information on the standard Storage Profiles provided with the FS1-2 Flash Storage System.  These Storage Profiles were considerably revised as of Release 6.1.3.  The profiles are listed by application category and the detailed Quality of Service and preferred Storage Classes are listed for each profile.

Scope

 This document is intended for Storage Administrators and Oracle support personnel involved in the installation or configuration of the FS1.

Details

These are the standard performance profiles as of Release 6.1.3, with their QoS parameters and Storage Class preferences as shown in the Oracle FS System Manager GUI. Systems that are upgraded to this release without a System Reset may have additional deprecated profiles, or profiles where the QoS parameters or preferred storage classes are not the same as those in this release.

  • Initial Release 6.1.2 changed the names and QoS parameters of several profiles and deprecated other profiles. Existing user volumes created on releases lower than 6.1.2 are not modified on the upgrade to 6.1.2 to match the newer recommended parameters. New volumes created on release 6.1.2 will have the QoS parameters in the table below but may not have the updated preferred Storage Classes of release 6.1.3. Systems which were reset on the upgrade to 6.1.2 will only have the newer profiles as noted below but new volumes created on release 6.1.2 will have the QoS parameters in the table below but may not have the updated preferred Storage Classes of release 6.1.3.

  • Controlled Release 6.1.3 changed the Storage Class order of preference on several profiles to those in the table below. Existing user volumes created on releases lower than 6.1.3 are not modified on the upgrade to 6.1.3 to match the new storage class preferences. New volumes created on 6.1.3 or higher will have the storage class preferences below.

  • See  FS System: Migrating User LUNS Created on FS1-2 Release 6.1.2 or Below to the Standard Storage Profiles of Release 6.1.3 for how to migrate existing volumes to match the updated preferences.

Standard Performance Profiles

Type
Application
Name
Performance Profile
RAID Level1 Read Ahead2 Priority3 Stripe Width4 Writes5 Preferred Storage Classes6
Backup Disk to Disk Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Disk Staging Double Aggressive Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
General Purpose General Purpose Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Generic Logs Double Normal Low Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Streaming Media (General - Read) Double Aggressive Low Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Streaming Media (Hi Res - Read) Double Aggressive High Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Streaming Media (Render/Edit) Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Performance Benchmark Single Aggressive Premium All WB PerfSSD, CapSSD, PerfDisk, CapDisk
Web Server Double Normal Medium Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Oracle DB Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Oracle DB ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Oracle WebCenter Web Viewable Repository Double Normal Medium Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Native File Repository Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Search Index Table Space Double Normal Medium Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Redo Log Group Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Backup & Recovery Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Microsoft Exchange Database Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Transaction Logs Double Normal Medium Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
SMTP/MTA Queue Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Microsoft Exchange 2010 Database Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Transaction Logs Double Normal Medium Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
SMTP/MTA Queue Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
MS SQL Server TPCC Logs Double Normal Low Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
TPCC Data Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Quorum Disk Single Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp DB Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
System DB Double Aggressive Low Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Backup Files Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
MaxRep Home Double Aggressive High Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Backup Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Retention Double Normal High Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
J D Edwards Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
App Space Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
PeopleSoft Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
App space Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
SAP Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
App space Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Siebel Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
App space Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Oracle EBS Control Files Single Normal Premium Auto WB PerfSSD, CapSSD, PerfDisk, CapDisk
DB Index Single Normal High Auto WB CapSSD, PerfDisk, CapDisk, PerfSSD
DB Tables Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Temp Files Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Online Redo Logs Single Normal Premium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
Archive Logs Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
App space Single Normal Medium Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data OLTP Mirrored Normal High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Data DSS Single Aggressive High Auto WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM Redo and control files Single Conservative Premium All WB PerfDisk, CapDisk, CapSSD, PerfSSD
ASM FRA Double Normal Archive Auto WB CapDisk, PerfDisk, CapSSD, PerfSSD
Type
Application
Name
Performance Profile
RAID Level1 Read Ahead2 Priority3 Stripe Width4 Writes5 Preferred Storage Classes6

RAID Level -- RAID Protection Level1

Any given drive group may contain user volumes with multiple RAID types.

  • Single - Single Parity - RAID5
  • Double - Double Parity - RAID6
  • Mirrored - RAID10

Read Ahead -- Read Ahead Strategy2

As a host read is processed, additional sequential data reads are performed internally to bring subsequent LBA ranges into Controller cache based on the presumption the host will also be reading that data.

  • Normal - Normal, no read ahead
  • Conservative - Moderate read ahead
  • Aggressive - Maximum read ahead

Priority -- Quality of Service Priority3

QoS Priority is a combination of the internal resource allocation and queueing priority and the physical striping of data across drive groups. User volumes will be striped in equal increments across the optimal number of drive groups if free space on the optimal number of groups is available. If the system does not contain the optimal number of drive groups for a QoS priority, the user volumes will be striped across the available groups, which reduces the spindle/SSD count and may result in less than optimal performance for the selected profile. If there is not enough space on the optimal number of drive groups, the system may have to stripe volumes across more than the optimal number. In either case, if additional storage is added, the system will present the option to re-stripe the data across the added drive groups.

  • Premium - Optimal striping 8 Drive groups
  • High - Optimal striping 8 Drive groups
  • Medium - Optimal striping 6 Drive groups
  • Low - Optimal striping 4 Drive groups
  • Archive - Optimal striping 4 Drive groups

Stripe Width -- Optimal Number of Drive Groups4

The Auto setting means the system will attempt to place user volumes on the optimal number of drive groups for the QoS priority if equal increments of free space are available. The All setting means that the system will stripe user volumes across all available drive groups in the available Storage Class and Storage Domain.

  • Auto Auto-select - Based on QoS Priority and number of groups available
  • All - Stripe across all available Drive Groups in the Storage Class and Domain. Increased risk of access contention unless applications and domains are carefully managed.

Writes -- Write Caching5

WB stores host writes in Controller Flash Backed Memory on the buddy, and returns a positive response to the host before the data is flushed to the drive groups. WT stores host writes on the drive groups before a positive response is returned to the host.

  • WB - Write Back - Use Flash Backed Memory
  • WT - Write Through - Bypass Flash Backed Memory

Preferred Storage Classes6

As volumes are created, the system will place the volumes on the preferred storage class if it exists in the system. If that storage class does not exist, the system will place volumes on the next storage class as listed in order of preference for the specific profile.

  • CapDisk - "Capacity Disk" - Hard drives optimized for lowest cost per byte
  • PerDisk - "Performance Disk" - Hard drives optimized for higher performance
  • CapSSD - "Capacity SSD" - SSD drives optimized for lowest cost per byte
  • PerfSSD - "Perormance fSSD" - SSD drives optimized for higher performance

 

References

<NOTE:1952045.1> - FS System: Migrating User LUNS Created on FS1-2 Release 6.1.2 or Below to the Standard Storage Profiles of Release 6.1.3

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.