Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1947276.1
Update Date:2017-09-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1947276.1 :   SPSUN4V-8001-U3 - Excessive coprocessor correctable errors (CEs)  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T7-4
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
  • Solaris (SPARC)
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

SPARC T7-4
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC

Purpose

 Additional Information for Message ID: SPSUN4V-8001-U3

Details

 Type

Hardware Fault
   fault.cpu.generic-sparc.coprocessor

Severity

Major

Description

Excessive correctable errors have been detected in a coprocessor.

Automated Response

No system response required.

Impact

System performance may be reduced.

Suggested Action for System Administrator

The administrator should arrange to have the FRU containing the faulty component replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback