Solution Type
Predictive Self-Healing Sure
Solution
1938990.1
:
SPSUN4V-8002-0R - Sparc Co-Processor Timeout
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- Oracle MiniCluster Specific Software
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Oracle MiniCluster Specific Software
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC
Purpose
Additional Information for Message ID: SPSUN4V-8002-0R
Details
Type: Hardware Fault
fault.cpu.generic-sparc.coprocessor-timeout
Severity: Major
Description
During normal operations, a Sparc coprocessor timeout was asserted when attempting to process and instruction set.
Automated Response
The hardware has automatically deconfigured the cpu to isolate the failure.
Impact
The system's capacity to transmit between CPU chips has been reduced.
Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty component reviewed and/orreplaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.