Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1938978.1
Update Date:2017-09-20
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1938978.1 :   SPSUN4V-8002-14 - Sparc Chip Excessive Correctable Errors  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Oracle MiniCluster Specific Software
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
References


Applies to:

Oracle MiniCluster Specific Software
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC

Purpose

Provide additional information for message ID: SPSUN4V-8002-14

Details

Type: Hardware Fault

           fault.cpu.generic-sparc.chip-nr

Severity: Critical

Description
The number of correctable errors in internal memory associated with this processor have exceeded acceptable levels.

Automated Response
The system may attempt to avoid using internal memory associated with this processor.

Impact
System performance may be affected.  No data has been lost.

Suggested Action for System Administrator
The administrator should arrange to have the FRU containing the faulty processor replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback