Asset ID: |
1-79-1938773.1 |
Update Date: | 2017-09-20 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1938773.1
:
SPSUN4V-8001-QR - Internal coherency link fault
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC T7-2
- SPARC M7-16
- SPARC T7-1
- Solaris (SPARC)
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
SPARC T7-4
SPARC
Purpose
Additional Information for Message ID: SPSUN4V-8001-QR
Details
Type
- Hardware Fault
- fault.cpu.generic-sparc.c2c-link-internal
Severity
- Major
Description
- An internal fault has been detected within the chip-to-chip coherency link between two cpus.
Automated Response
- The affected coherency link may be deconfigured on the next system restart.
Impact
- System performance may be affected.
Suggested Action for System Administrator
- The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required. -
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments
This solution has no attachment