1938758.1
:
SPSUN4V-8001-NQ - Excessive correctable errors in an IO chip
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M7-8
- SPARC M8-8
- Oracle SuperCluster M8 Hardware
- SPARC T7-2
- Solaris (SPARC)
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
SPARC T7-4
Oracle SuperCluster M7 Hardware
SPARC M7-8
Solaris (SPARC)
SPARC M7-16
SPARC
Purpose
Additional Information for Message ID: SPSUN4V-8001-NQ
Details
Type
- Hardware Fault
- fault.asic.io-bridge.chip
Severity
- Major
Description
-
An IO chip is reporting excessive internal correctable errors.
Automated Response
-
No system response required.
Impact
-
System performance may be affected. No data has been lost.
Suggested Action for System Administrator
- The administrator should arrange to have the FRU containing the faulty component replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)