Solution Type Predictive Self-Healing Sure Solution 1937692.1 : SPT-8001-V4 - Component Temperature Low Warning
In this Document
Applies to:Oracle MiniClusterSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 SPARC PurposeAdditional information for SPT-8001-V4 - Component Temperature is under normal threshold. - A component within the chassis has asserted a low temperature warning. DetailsType: Fault fault.chassis.temp.under.minor
Description.The message ID: SPT-8001-V4 indicates that the fault management function has determined one of the chassis component's temperature is under normal threshold, and a warning has been asserted. Temperature conditions generally result from conditions outside the system. (ie room temp, blocked inlets). Automated ResponseThe service-required LED on the chassis will be illuminated. ImpactServer performance may be affected. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine the action to resolve the situation. Attachments This solution has no attachment |
||||||||||||||||||||||||
|