Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1638836.1
Update Date:2014-04-15
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1638836.1 :   Exalogic Patch Set Update (PSU) Release v2.0.6.1.1 (Linux - Physical - Exalogic X4-2) for April 2014  


Related Items
  • Exalogic Elastic Cloud X4-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud Software
  •  
Related Categories
  • PLA-Support>Eng Systems>Exalogic/OVCA>Oracle Exalogic>MW: Exalogic Core
  •  




In this Document
Purpose
Scope
Details
 Prerequisites
 April 2014 PSU Content
 Patch Testing and Application Guidelines
 Appendices
 Appendix A: Fixed Bugs List
 Appendix B: Patching Troubleshooting Guide
 Appendix C: Patching Known Issues
References


Applies to:

Exalogic Elastic Cloud X4-2 Hardware
Oracle Exalogic Elastic Cloud Software - Version 2.0.6.1.0 to 2.0.6.1.1
Linux x86-64

Purpose

Oracle Exalogic is an integrated hardware and software system designed to provide a complete platform for a wide range of application types and widely varied workloads. It combines optimized Oracle Fusion Middleware Software like WebLogic Server, JRockit, Coherence with industry-standard Sun Server and Storage hardware and Infiniband networking. The purpose of this document is to provide specific information around a specific Patch Set Update for that system.

Scope

This document is intended to provide a guide, to senior engineers with strong system administration skills, for patching all the firmware and operating system components of Exalogic compute nodes, storage nodes and switches.

Details

This Document provides information about the Oracle Exalogic Patch Set Update for Oracle Linux x86-64 (64-bit) for Exalogic X4-2 system running EECS 2.0 in a physical (not virtual) configuration. Before applying the patches included in this PSU, be sure to back up your current installation, configuration files, and any user-specific artifacts.

Note:

This Exalogic PSU is not applicable to Exalogic X2-2 & X3-2 systems.

Prerequisites

  1. Review the official April 2014 PSU/CPU Document ID : 1618213.1 - Patch Set Update and Critical Patch Update April 2014 Availability Document
  2. Review the general PSU information for Exalogic in Document ID : 1314535.1 - Exalogic Patch Set Updates (PSU) Master Note

 

April 2014 PSU Content

This Exalogic Infrastructure Patch Set Update (PSU) is cumulative and applicable to Exalogic X4-2 systems running v2.0.6.1.0 of the Exalogic Infrastructure in the physical (not virtual) configuration:

  • Exalogic X4-2:
    • v2.0.6.1.0

This Oracle Exalogic Patch Set Update includes patches/updates for Oracle Exalogic Infrastructure, Oracle Middleware, Oracle JRockit, Oracle WebLogic Server and Oracle Coherence.

For customers running JRockit, Coherence, and/or WebLogic Server on Exalogic, it should be noted that, middleware patches are not applied automatically along with the Exalogic PSU installation. Middleware patches are separate installs and are highly recommended yet OPTIONAL. The PSU patch explodes to the following directories. Please make sure to follow the README files for each patch as directed by the README file in the 18178960 directory:

18178960
|
|- README.txt 

|- README.html 

|- Infrastructure/ 
|     -2.0.6.1.1 
|          - BaseImage 
|          - NM2-GW 
|          - NM2-36p 
|          - exapatch_descriptor.py 
|          - README.html 
|          - README.txt 

|- Middleware/ 
|     - Coherence/ 
|          - 3.7.1.12/ 
|              - p18385410_371_Generic.zip 
|              - README.txt 

|     - JRockit/ 
|          - 1.6.0_75/ 
|              - jrockit-jdk1.6.0_75-linux_x86_64.zip 
|              - README.txt 

|     - WebLogic/ 
|          - 10.3.6.0.8/ 
|              - WebLogic.zip 
|              - README.txt 

|     - Oracle Traffic Director/ 
|          - 11.1.1.7.0/ 
|              - p17840779_111170_Linux-x86-64.zip 
|              - README.txt 
|

Patch Testing and Application Guidelines

  1. Read and review Exalogic Document ID : 1638838.1 - Exalogic April 2014 PSU - 2.0.6.1.1 (Linux - Physical - Exalogic X4-2) Infrastructure Upgrade Guide, for patch installation instructions, known issues and special notes. 
  2. Validate patch installation on the TEST system.
    1. Apply the patch to the TEST system that is of equivalent capability and configuration as the PRODUCTION system.
    2. Evaluate technologies and practices that may reduce downtime and risk
    3. Automate steps to reduce human error.
    4. Define, document, and test fallback procedures required if a patch must be rolled back.
    5. Before and after patch application, perform healthchecks using Exachk script to verify software, hardware, and firmware versions using the Document ID : 1449226.1- Exachk Health-Check Tool for Exalogic
  3. Validate patch functionality on the TEST system.
    1. If applying the patch to address a specific issue, verify that the patch provides the functionality desired.
    2. Verify there is no performance, availability, or operational regression while running workload that is representative to that which runs on the PRODUCTION system. This requires comparing metrics captured before and after patch application on the TEST and against metrics captured on the PRODUCTION system.
  4. Apply the patch on the PRODUCTION system.
    1. Test application functionality with load if possible
    2. Before and after patch application, perform healthchecks using Exachk script to verify software, hardware, and firmware versions using the Document ID : 1449226.1- Exachk Health-Check Tool for Exalogic

Appendices

Appendix A: Fixed Bugs List

Please review Document ID : 1639329.1Exalogic Infrastructure April 2014 PSU - Fixed Bugs List . This document lists all the bugs went into the Exalogic April 2014 PSU

Appendix B: Patching Troubleshooting Guide

Please review Document ID : 1590392.1 Exalogic Infrastructure PSU Upgrade - Troubleshooting Guide . This document contains information and pointers to help you troubleshoot problems you encounter during Exalogic PSU Patching.

Appendix C: Patching Known Issues

Please review Document ID : 1571367.1Exalogic Infrastructure PSU Upgrade - Known IssuesThis document lists the known issues for Exalogic PSU Patching.

 

References

<NOTE:1449226.1> - Exachk Health-Check Tool for Exalogic
<NOTE:1329262.1> - How to Perform a Healthcheck on Exalogic
<NOTE:1314535.1> - Exalogic Patch Set Updates (PSU) Master Note

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback