Purpose

 Provide additional information for message ID: ISTOR-8000-2A

Details

 Disk Self-Test Failure

 

Type

Fault
fault.io.disk.self-test-failure

Severity

Critical

Description

Message ID: ISTOR-8000-2A indicates that the ILOM fault manager has applied diagnosis
to error reports indicating
One or more disk self tests failed.

Automated Response

None.

Impact

The disk has failed self tests.

Suggested Action for System Administrator

Replace the faulty disk identified in the "fmadm faulty" output.

Refer to the following document for the latest procedures for displaying event content
in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)