Asset ID: |
1-79-1637644.1 |
Update Date: | 2017-09-22 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1637644.1
:
ISTOR-8000-2A - Disk Self-Test Failure
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- SPARC T8-2
- SPARC T7-2
- SPARC T7-1
- x64 Platform product manufacturing
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
x64 Platform product manufacturing
SPARC T7-1
SPARC T7-2
SPARC T7-4
SPARC T8-1
Information in this document applies to any platform.
Purpose
Provide additional information for message ID: ISTOR-8000-2A
Details
Disk Self-Test Failure
Type
- Fault
- fault.io.disk.self-test-failure
Severity
- Critical
Description
- Message ID: ISTOR-8000-2A indicates that the ILOM fault manager has applied diagnosis
to error reports indicating One or more disk self tests failed.
Automated Response
- None.
Impact
- The disk has failed self tests.
Suggested Action for System Administrator
- Replace the faulty disk identified in the "fmadm faulty" output.
-
Refer to the following document for the latest procedures for displaying event content
in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)
Attachments