![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1626892.1 : Sun Fire V2xx, Netra 2xx, E220R, 420R, E450, Ultra xx, Netra T1xxx, SB1x00, SB2x00 Customer Actions: Commands to run
In this Document
Applies to:Sun Netra 1280 ServerSun Netra 1290 Server Sun Netra i Server Sun Ultra 45 Workstation Sun Enterprise 450 Server Information in this document applies to any platform. Purpose
****************************************************************************** This document provides the actions to be done by the Customer before and after the Field Engineer service action.
Details
TSC engineers: please copy/paste the following text into a public note of the Service Request
------------------------------------------------------ CUT HERE ---------------------------------------------------------------
Dear Customer, Prior to Field Engineer service actions: Note: Hot-Pluggable devices (such as disks) can be removed and installed while the system is running, but require certain Solaris commands (admin tasks) to complete the operation. When replacing a disk, the operating system should be configured by the customer such that the disk drive is free for replacement, e.g. the disk may be part of Solaris Volume Manager, Veritas Volume Manager, mounted file-system, raw partitions, etc. A data backup is not a prerequisite but is a wise precaution.Note: When replacing a drive that is part of a RAID volume (V215/V245 only) Troubleshooting RAID boot issues on V215/V245, V440/V445, T1000/T2000 (Doc ID 1002929.1) Reconfigure the drive into the server as previously configured (part of a RAID volume, SVM volume, mounted file system, etc). For V215/V245 refer to: Document: 1007005.1 How to activate a RAID volume on T1000/T2000, V215/V245/V445, T5120/T5220, T5140/T5240/T5440 Servers
See the System Admin Guides and/or System Service Manuals for the appropriate platform located at: Netra T1xxx: http://docs.oracle.com/cd/E19102-01/nt1.ac200.srvr/index.html
See also these documents for assistance in preparing the disk for replacement and reconfiguring the disk into Solaris: For SVM/ : 1010946.1 General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris SVM Admin Guide: http://docs.oracle.com/cd/E19253-01/816-4520/troubleshoottasks-33506/index.html For VxVM: 1010946.1 General Guidance for Diagnosis (Disk Failures/Errors) and Replacing Internal Server Disks and JBOD Disks within Solaris For ZFS: 1002753.1 How to Replace a Drive in Solaris[TM] ZFS For raidctl: 1013107.1 How to Identify Solaris Hardware RAID Status
------------------------------------------------------ CUT HERE --------------------------------------------------------------- Attachments This solution has no attachment |
||||||||||||||
|