Asset ID: |
1-79-1626274.1 |
Update Date: | 2014-05-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1626274.1
:
Sun Netra X4270 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
|
In this Document
Applies to:
Sun Netra X4270 Server - Version All Versions and later
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Netra X4270 Server, with the firmware version which fixes that issue or the workaround
These issues are outlined in more detail on the internal Sun Netra X4270 Server Current Product Issues <Document: 1362253.1> page
Details
Symptom | Details | Resolution/Workaround |
HOST_LAST_POWER_STATE feature not working in ILOM |
Following ILOM policy does not work
-> set /SP/policy HOST_LAST_POWER_STATE=enabled
|
Issue fixed in firmware version SW1.1
Resolution: Update ILOM/BIOS firmware to latest version.
|
Server does not boot and service(Amber) LED lit. |
ILOM event log may show below error
Memory : BIOS : Configuration Error : MRC error Major 0xE8
ILOM FMA may show below error report
fault.memory.intel.dimm.none
|
Workaround: Cold reboot server [Power off server -> Remove all power cables from server -> Wait 5 mins -> Re-insert power cables -> Start server]
Issue fixed in system firmware release SW1.2.1.
Resolution: Update ILOM/BIOS firmware to latest version.
|
Attachments
This solution has no attachment