Asset ID: |
1-79-1626266.1 |
Update Date: | 2014-05-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1626266.1
:
Sun Netra X4250 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
|
In this Document
Applies to:
Sun Netra X4250 Server - Version All Versions and later
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Netra X4250 Server, with the firmware version which fixes that issue or the workaround
These issues are outlined in more detail on the internal Sun Netra X4250 Server Current Product Issues <Document: 1345644.1> page
Details
Symptom | Details | Resolution/Workaround |
Solaris panic |
FMA(fmdump -eV) will show error report similar to
Mar 01 13:07:00.6156 ereport.cpu.intel.nb.fbd.otf
|
Workaround:
- Update ILOM/BIOS firmware to latest version.
- Add following entry to /etc/system
'set intel_nb5000:nb5000_mask_bios_fbd=7'
Note: Ensure all other entries relating to nb5000 are removed from /etc/system.
|
Server fails to boot with microcode error |
Unable to boot due to the following bios errors after MB is replaced.
Error (0160): Processor missing microcode . .
Press... F1 tp Resume, F2 to run Setup
|
Resolution: Update ILOM/BIOS firmware to latest version.
|
Attachments