Purpose

This document outlines the top non-hardware issues our customers encounter on the Sun Netra X4250 Server, with the firmware version which fixes that issue or the workaround


These issues are outlined in more detail on the internal Sun Netra X4250 Server Current Product Issues <Document: 1345644.1> page

Details

Documentation NetraX4250 Patches&Firmware NetraX4250  My Oracle Support Community (MOSC) Sun x86 Systems Oracle System Handbook NetraX4250

 

SymptomDetailsResolution/Workaround
Solaris panic

  FMA(fmdump -eV) will show error report similar to 

Mar 01 13:07:00.6156 ereport.cpu.intel.nb.fbd.otf

Workaround:

  1. Update ILOM/BIOS firmware to latest version.
  2. Add following entry to /etc/system
    'set intel_nb5000:nb5000_mask_bios_fbd=7'

Note: Ensure all other entries relating to nb5000 are removed from /etc/system.

Server fails to boot with microcode error

Unable to boot due to the following bios errors after MB is replaced.

Error (0160): Processor missing microcode

. 

Press... F1 tp Resume, F2 to run Setup

Resolution: Update ILOM/BIOS firmware to latest version.