Asset ID: |
1-79-1626213.1 |
Update Date: | 2014-05-30 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1626213.1
:
Sun Fire X4540 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
|
In this Document
Applies to:
Sun Fire X4540 Server - Version All Versions and later
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Fire X4540 Server, with the firmware version which fixes that issue or the workaround
These issues are outlined in more detail on the internal Sun Fire X4540 Server Current Product Issues <Document: 1350665.1> page
Details
Symptom | Details | Resolution/Workaround |
Server boot process hangs while initializing HBA |
1068E firmware hangs upon SAS Discovery Error on port.
Unaddressable device found
|
Issue fixed in LSI BIOS v6.26.00 FW 1.27.92 (Patch 16044285: X4540 SW 2.3.2) Resolution: Update LSI BIOS firmware to latest
|
ILOM 3.0 WebGUI doesn't work with Firefox 6 |
|
Resolution: Update ILOM firmware to latest version.
|
DMA error in operating system. |
mpt driver reports "DMA can't cross 4GB boundary due to errata" |
This error is not critical and safe to ignore.
|
Unable to set ILOM IP address in BIOS |
|
Issue fixed in ILOM version SW1.2 Resolution: Update ILOM firmware to latest version.
|
Server OK LED is OFF, though server is working |
LED does illuminate during the LED test.
|
Issue fixed in ILOM firmware 3.0. Resolution: Update ILOM firmware to latest version.
|
Attachments
This solution has no attachment