Sun Fire X4470 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
|
In this Document
Applies to:
Sun Fire X4470 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Fire X4470 Server, with the firmware version which fixes that issue or the workaround
These issues are outlined in more detail on the internal Sun Fire X4470 Server Current Product Issues (Doc ID 1353080.1) page
Details
Symptom | Details | Resolution/Workaround |
Solaris FMA showing all CPUs as failed. |
FMA error code Intel8001-ND Major. However ILOM does not report any failure. This is false alarm and does not need hardware replacement.
|
Workaround: Clear FMA errors by using fmadm repair procudure.
# fmadm repaired <event-id>
|
Cannot -> start /SYS after upgrading firmware. |
When ILOM updated from 3.0.14.10(SW 1.2.1) to 3.0.16.13.a(SW 1.4) |
Workaround: Downgrade firmware to SW 1.2.1
|