Purpose

 This document outlines the top non-hardware issues our customers encounter on the Sun Netra Server X3-2, with the firmware version which fixes that issue or the workaround.


These issues are outlined in more detail on the internal Sun Netra Server X3-2 Current Product Issues (Doc ID 1451961.1) page

Details

Documentation NX3-2  -  Patches&Firmware NX3-2  -  My Oracle Support Community (MOSC) Sun x86 Systems  -  Oracle System Handbook NX3-2

 

SymptomDetailsResolution/Workaround

RAID disk initialization taking up to 24 hours to complete

No errors messages will be reported. Problem manifests itself in the extremely slow initialization of RAID configured disks

Fix delivered in HBA FW 1.29.08.0, available at:
http://www.lsi.com/sep/Pages/oracle/sg_x_sas6-int-z.aspx