Sun Netra Server X3-2 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: TELCO-NETRA
|
In this Document
Applies to:
Netra Server X3-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Netra Server X3-2, with the firmware version which fixes that issue or the workaround.
These issues are outlined in more detail on the internal Sun Netra Server X3-2 Current Product Issues (Doc ID 1451961.1) page
Details
Symptom | Details | Resolution/Workaround |
RAID disk initialization taking up to 24 hours to complete
|
No errors messages will be reported. Problem manifests itself in the extremely slow initialization of RAID configured disks
|
Fix delivered in HBA FW 1.29.08.0, available at: http://www.lsi.com/sep/Pages/oracle/sg_x_sas6-int-z.aspx
|