Asset ID: |
1-79-1618522.1 |
Update Date: | 2018-03-26 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1618522.1
:
Sun Server X4-2 Symptoms and Solutions
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x86: Sun Server X4
|
In this Document
Applies to:
Sun Server X4-2 - Version All Versions and later
Information in this document applies to any platform.
Purpose
This document outlines the top non-hardware issues our customers encounter on the Sun Server X4-2, with the firmware version which fixes that issue or the workaround
These issues are outlined in more detail on the internal Sun Server X4-2 and X4-2L Current Product Issues (Doc ID 1579257.1) page
Details
Symptom | Details | Resolution/Workaround |
Warning Notice |
PCI Cards using 64-bit prefetch buffer will create following error with Solaris 10 1/13
pci_autoconfig: [ID 241636 kern.notice] NOTICE: unsupported 64-bit prefetch memory on pci-pci bridge [0/2/2]
This notice message will not have any impact on the productivity of the system.
|
64-bit prefetch buffer is unsupported with Oracle Solaris 10.
The current workaround is to disable "PCI 64 Bit Resource Allocation" in System BIOS (see Sun Server X4-2 BIOS IO Menu Selections)
or update your system to Oracle Solaris 11.1. Further investigation is still in progress by engineering.
|
Attachments
This solution has no attachment