Purpose
This lists how to run queries on metadata from explosum & snapper output on cores3 servers.
Details
The Explosum & Snapper tools gather hardware related metadata from an Explorer & ILOM Snapshot data. These tools are targeted for VSP products, but can be used on explorers & snapshots from other SPARC or X64 products.
File /share/summarytools/log.txt contains a log of Explorers & Snapshots that the tools were run against on the ISDE server.
These tools will also store FRU & event data for most platform types if the Explorer contains a valid date, Serial number, & if run from an SR directory on ISDE. Each server will contain it's own set of entries as shown below (Sample Raw Data). The first line contains a list of Explorer/Snapshot dates with the associated SR#. The second section contains a list of installed FRUs & associated FRU data like it's serial number. If multiple FRU data is listed, then the later entries indicate the FRUs that have been replaced/moved. The final type of data is the ordered event list of the last 256 events. This lists ILOM & Solaris reboots (listing FW version), ILOM FW upgrades, some ereports & faults, & kernel Warnings. This data is used in the timelines listed at the end of Explosum's & Snapper's Summaries which provides the TSE a view of combined Explorer, Snapshot, & older SR data. The db tool can be used to query this data.
The man page data for the db tool is as follows:
db Scan db for problems & sizes
db "?" Command syntax
db MultiFRU [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
List Systems with multiple FRU replacements
db Replaced [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
List Systems/FRU replacements
db ListFRU [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
List a System's FRUs [List only matching strings/params]
db FRU Platform/FRUSer#/SR/fruType/date [fruType/matchString/date]
List FRU matches [or specific FRU] that contain parameters
db SR SR#/Ser# [matchString/date] [matchString/date]
List systems that are associated with SR#
db Chassis Ser# List all information for a Chassis Serial #
db Platform/Ser#/matchString [matchString/date] [matchString/date] [matchString]
List events with matching string
Notes:
1. Parameters are pre-screened for dates, SR #, Platform type, Chassis or FRU serial number.
If none of these, is then determined to be a keyword to search events.
All event related parameters are ORed (listed if one matches) for each event,
but all FRU, chassis & date parameters are ANDed (listed if all match).
2. Date syntax = yy/mm or yy/mm/dd or yy/mm/dd-hh:mm
If 2 dates input, the first is matches if an entry is older & if 2nd newer
3. Valid platform names are: T5120, T5220, N5220, T5140, T5240, N5440, T5440, T6320, T6340, C3260,
T3-1, N3-1, T3-2, T3-4, T3-1B, N31BA, T4-1, N4-1, T4-2, N4-2, T4-4, T4-1B,
T5-2, T5-4, T5-8, T5-1B, M5-32,
M3000, M4000, M5000, M8000, M9000, M10.1, M10.4, M104S
T4 or T5 will match all T4 or T5 platforms.
4. FRU names must be the same as listed in the Explorer or Snapshot including '/'s. The only FRU names
without '/'s are:
"MB", "FB", "SASBP", "MIDPLANE", "CMM", "RIO", "FIO", "RCSA", "SIB", "DBP", "PDB", "PADCRD"
"CM#", "PS#", "NEM#", "SASBP#", "P#", "HDD#", "PM#"
Some examples db are:
List the FRUs related to Chassis Serial number & dates detected in system:
amogg0021% /share/summarytools/db ListFRU AK00121322
db revision 2.15 _ListFRU_ f__ __ h_AK00121322_ __ e__ __
FRUs T5-2 AK00121322 P0/M0 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0HEE
FRUs T5-2 AK00121322 P0/M1 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0JM6
FRUs T5-2 AK00121322 P0/M2 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0JL8
FRUs T5-2 AK00121322 P0/M3 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0JM4
FRUs T5-2 AK00121322 P1/M0 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1320UG0GJE
FRUs T5-2 AK00121322 P1/M1 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0JNH
FRUs T5-2 AK00121322 P1/M2 - 14/03/13-13:59:27 Oracle Corpo 7064940 465769T+1321UG0HDV
FRUs T5-2 AK00121322 P1/M2 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0HET
FRUs T5-2 AK00121322 P1/M3 - 14/03/13-13:59:27 Oracle Corpo 7064940 465769T+1321UG0HET
FRUs T5-2 AK00121322 P1/M3 - 13/11/20-19:28:45 Oracle Corpo 7064940 465769T+1321UG0HDV
FRUs T5-2 AK00121322 P0/M0/B0/C0/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211748CB05
FRUs T5-2 AK00121322 P0/M0/B0/C1/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211718CAF9
...
FRUs T5-2 AK00121322 P1/M2/B0/C0/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728C37558
FRUs T5-2 AK00121322 P1/M2/B0/C0/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211788CAFC
FRUs T5-2 AK00121322 P1/M2/B0/C1/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728237556
FRUs T5-2 AK00121322 P1/M2/B0/C1/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211758CB00
FRUs T5-2 AK00121322 P1/M2/B1/C0/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113273D4CAB71
FRUs T5-2 AK00121322 P1/M2/B1/C0/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211718CB03
FRUs T5-2 AK00121322 P1/M2/B1/C1/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728737539
FRUs T5-2 AK00121322 P1/M2/B1/C1/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211768CB02
FRUs T5-2 AK00121322 P1/M3/B0/C0/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211788CAFC
FRUs T5-2 AK00121322 P1/M3/B0/C0/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728C37558
FRUs T5-2 AK00121322 P1/M3/B0/C1/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211758CB00
FRUs T5-2 AK00121322 P1/M3/B0/C1/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728237556
FRUs T5-2 AK00121322 P1/M3/B1/C0/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211718CB03
FRUs T5-2 AK00121322 P1/M3/B1/C0/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113273D4CAB71
FRUs T5-2 AK00121322 P1/M3/B1/C1/D0 - 14/03/13-13:59:27 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD0113211768CB02
FRUs T5-2 AK00121322 P1/M3/B1/C1/D0 - 13/11/20-19:28:45 Hynix Semico HMT31GR7CFR4A-PB 7042208 00AD01132728737539
FRUs T5-2 AK00121322 MB - 14/03/13-13:59:27 Oracle Corpo 7076601 465769T+1335UL06A9
FRUs T5-2 AK00121322 MB - 13/11/20-19:28:45 Oracle Corpo 7076601 465769T+1324UL059D
FRUs T5-2 AK00121322 MB/SP - 13/11/20-19:28:45 Oracle Corpo 7066335 465769T+1323UF09H9
FRUs T5-2 AK00121322 CM0 - 13/11/20-19:28:45 Oracle Corpo 7076601 465769T+1324UL059D
List Chassis Serial #s related to SR #(s):
amogg0021% /share/summarytools/db SR AK00121322
db revision 2.15 _SR_ f__ __ h_AK00121322_ __ e__ __
SRs T5-2 AK00121322 - 3-8698079871 14/03/13-13:59:27, 3-7675377660 13/11/20-19:28:45
List events between a date range:
amogg0021% /share/summarytools/db 13/12 13/11 VCORE_POK
db revision 2.10 _13/12_ _13/11_ _VCORE_POK_ __
T3-1 1045BDR17C 3-8124433291 13/11/20-01:25:33 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-1 1115BDR4DA 3-8062200781 13/11/07-04:20:15 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-1 1116BDR5C2 3-8074646081 13/11/08-22:45:42 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-1 1142BDR6C8 3-8085715381 13/11/12-09:04:40b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP0/VCORE_POK
T3-1 1142BDR6C8 3-8085715381 13/11/12-08:32:18b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP0/VCORE_POK
T3-1 1142BDR6C8 3-8085715381 13/11/11-13:48:35a ereport.chassis.power.glitch-fatal@/sys/mb /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-2 1102BDR70A 3-8172302291 13/11/30-16:16:59 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-2 1102BDR70A 3-8172302291 13/11/16-14:15:00 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-2 1126BDRA21 3-8076630651 13/11/20-13:21:51 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T3-2 1126BDRA21 3-8076630651 13/11/10-07:16:13 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
T4-1 1230BDYAA1 3-8048491001 13/11/04-16:46:31b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP0/VCORE_POK
T4-1 1230BDYAA1 3-8048491001 13/11/04-16:28:36b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP0/VCORE_POK
T4-1 1230BDYAA1 3-8048491001 13/11/03-22:35:52a ereport.chassis.power.glitch-fatal@/sys/mb /SYS/MB/CMP0/VCORE_POK_GLITCH
T4-2 1150BDY02C 3-8170645441 13/11/29-04:28:00a 00 ereport.chassis.power.glitch-fatal@/sys/mb /SYS/MB/CMP0/VCORE_POK_GLITCH
T4-2 1240BDY37C 3-8042637471 13/11/03-04:12:43b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP0/VCORE_POK
T4-2 1240BDY37C 3-8042637471 13/11/03-03:13:53a ereport.chassis.power.glitch-fatal@/sys/mb /SYS/MB/CMP0/VCORE_POK_GLITCH
T4-2 1242BDY855 3-8076318861 13/11/10-05:31:11b ereport.chassis.poweron.fail-asserted@/sys/mb /SYS/MB/CMP1/VCORE_POK
T4-2 1242BDY855 3-8076318861 13/11/10-00:57:38a ereport.chassis.power.glitch-fatal@/sys/mb /SYS/MB/CMP1/VCORE_POK_GLITCH
T4-2 1249BDYC85 3-8130414056 13/11/20-19:57:06 ereport.chassis.power.glitch-fatal@/SYS/MB /SYS/MB/CMP0/VCORE_POK_GLITCH
List the chassis which contains (or contained) a FRU serial #:
amogg0021% /share/summarytools/db FRU 1125B2099P
db revision 2.10 _FRU_ _1125B2099P_ __ __
FRUs T3-1 1127BDRD13 MB - 5030 CELESTI 541-3857 1005LCB-1125B2099P
List T5-2 servers that had FRU multiple non-DIMM FRU replacements/swaps after February 2014:
amogg0021% /share/summarytools/db MultiFRU T5-2 14/03
db revision 2.15 _MultiFRU_ f__ __ h_T5-2_ __ e__ __
MultiRep FRUs T5-2 AK00121322 P1/M2 - 14/03/13-13:59:27 Oracle Corpo 465769T+1321UG0HDV
Replaced FRUs T5-2 AK00121322 P1/M3 - 14/03/13-13:59:27 Oracle Corpo 465769T+1321UG0HET
Replaced FRUs T5-2 AK00121322 MB - 14/03/13-13:59:27 Oracle Corpo 465769T+1335UL06A9
MultiRep FRUs T5-2 AK00131878 PS0 - 14/03/19-10:38:06 Emerson Netw 476856F+1217CD00FE
Replaced FRUs T5-2 AK00131878 PS1 - 14/03/19-10:38:06 Emerson Netw 476856F+1225CD01GA
MultiRep FRUs T5-2 AK00142748 MB - 14/03/02-00:19: Oracle Corporati 465769T+1324UL053V
Replaced FRUs T5-2 AK00142748 FB - 14/03/02-00:19: 9615 HON HAI PRE 464507L+132212026W
MultiRep FRUs T5-2 AK00169587 P1/M2 - 14/03/20-11:11: Oracle Corporati 465769T+1347UG16TK
Replaced FRUs T5-2 AK00169587 P1/M3 - 14/03/20-11:11: Oracle Corporati 465769T+1347UG16T7
Replaced FRUs T5-2 AK00169587 MB - 14/03/20-11:11: Oracle Corporati 465769T+1322UL04X0
List T5-8 servers that had FRU multiple non-DIMM FRU replacements/swaps between Nov 2013 & Dec 15 2013:
amogg0021% db MultiFRU T5-8 13/12/15 13/11
db revision 2.11 _MultiFRU_ _T5-8_ _13/12/15_ _13/11_
MultiRep FRUs T5-8 AK00097225 MB - 13/12/02-21:28:22 Oracle Corpo 465769T+13235203PY
Replaced FRUs T5-8 AK00097225 P2 - 13/11/27-16:54:11 Oracle Corpo 465769T+133088047H
MultiRep FRUs T5-8 AK00136161 P1 - 13/11/26-10:42: Oracle Corpo 465769T+13318804AE
Replaced FRUs T5-8 AK00136161 PS0 - 13/11/26-10:42: POWER ONE 465776G+1314B204BE
Replaced FRUs T5-8 AK00136161 PS1 - 13/12/03-12:33:48 POWER ONE 465776G+1314B204V6
MultiRep FRUs T5-8 AK00136654 P0 - 13/11/26-10:41: Oracle Corpo 465769T+13068800MW
Replaced FRUs T5-8 AK00136654 P1 - 13/11/26-10:41: Oracle Corpo 465769T+1252880057
Replaced FRUs T5-8 AK00136654 P2 - 13/11/26-10:41: Oracle Corpo 465769T+13248803JY
Replaced FRUs T5-8 AK00136654 P3 - 13/11/26-10:41: Oracle Corpo 465769T+13038800F7
List T5-2 servers that had FRU replacements between March 15 2014 & March 21. (If a PM moves, then all it's DIMMs are also considered replaced):
amogg0021% db Replaced T5-2 14/03/15 14/03/22
db revision 2.16 _Replaced_ f__ __ h_T5-2_ __ e__ __ d_14/03/15_ _14/03/22_
Replaced FRUs T5-2 AK00131878 PS0 - 14/03/19-10:38:06 Emerson Netw 476856F+1217CD00FE
Replaced FRUs T5-2 AK00131878 PS1 - 14/03/19-10:38:06 Emerson Netw 476856F+1225CD01GA
Replaced FRUs T5-2 AK00133969 MB - 14/03/17-15:49: Oracle Corporati 465769T+1324UL054E
Replaced FRUs T5-2 AK00149066 MB - 14/03/21-17:35: Oracle Corporati 465769T+1324UL055T
Replaced FRUs T5-2 AK00169587 P1/M2 - 14/03/20-11:11: Oracle Corporati 465769T+1347UG16TK
Replaced FRUs T5-2 AK00169587 P1/M3 - 14/03/20-11:11: Oracle Corporati 465769T+1347UG16T7
Replaced FRUs T5-2 AK00169587 MB - 14/03/20-11:11: Oracle Corporati 465769T+1322UL04X0
Replaced FRUs T5-2 AK00169587 P1/M2/B0/C0/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261176AB23
Replaced FRUs T5-2 AK00169587 P1/M2/B0/C1/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261146AB22
Replaced FRUs T5-2 AK00169587 P1/M2/B1/C0/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261176AB29
Replaced FRUs T5-2 AK00169587 P1/M2/B1/C1/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261146AB2A
Replaced FRUs T5-2 AK00169587 P1/M3/B0/C0/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261146AB28
Replaced FRUs T5-2 AK00169587 P1/M3/B0/C1/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261126AB2A
Replaced FRUs T5-2 AK00169587 P1/M3/B1/C0/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261156AB2D
Replaced FRUs T5-2 AK00169587 P1/M3/B1/C1/D0 - 14/03/20-11:11: Hynix Semiconduc HMT31GR7CFR4A-PB 00AD0113261166AB29
Replaced FRUs T5-2 AK00174588 P0/M3/B0/C0/D0 - 14/03/20-15:50:17 Hynix Semico HMT42GR7AFR4A-PB 00AD011405400281D5
Sample Raw Data:
T5-1 /AK00208327 (3-11912345678_16/01/11-13:44:07) (3-11901234567_15/12/22-15:12:) (3-10312345678_15/04/29-09:56:) (3-10312345678_15/03/10-23:20:) (3-9910123456_14/11/23-11:10:)
P0/M0 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WX5_7064940-03)
P0/M1 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WG4_7064940-03)
P0/M2 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WMK_7064940-03)
P0/M3 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WML_7064940-03)
MB (14/11/23-11:10:_Oracle Corporati__465769T+1413U4004X_7088094-03)
MB/SP (14/11/23-11:10:_Oracle Corporati__465769T+1410UF0JYF_7066335-01)
FB (14/11/23-11:10:_Oracle Corporati__464507N+1406HH002F_7057262-02)
HDD0 (14/11/23-11:10:_HITACHI_H109030SESUN300G_001408CTA8GN_)
HDD1 (14/11/23-11:10:_HITACHI_H109030SESUN300G_001408CS7MKF_)
SASBP (14/11/23-11:10:_Oracle Corporati__464507L+14011100BB_7039459-02)
PS0 (14/11/23-11:10:_Emerson Network __476856F+1409CD00LM_7060596)
PS1 (14/11/23-11:10:_Emerson Network __476856F+1409CD00LN_7060596)
P0/M0/B0/C0/D0 (16/01/11-13:44:07:_Samsung_M393B1K70DH0-YK0_00CE0314101584323D_7042208) (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314101584323C_7042208)
P0/M0/B0/C1/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE031410158432C3_7042208)
...
P0/M3/B1/C0/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314111586F660_7042208)
P0/M3/B1/C1/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314111586EDFE_7042208)
CM0 (16/01/11-13:44:07_Oracle Corpo__465769T+1413U4004X_7088094)
SP (16/01/11-13:44:07_Oracle Corpo__465769T+1410UF0JYF_7066335)
*3-11912345678_16/01/09-12:40:44r_au02 fbt: [ID 795213 kern.warning] WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/09-12:40:44a_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/09-12:39:43b_au02 igb: [ID 611667 kern.warning] WARNING: igb0: ioctl 82576 map not kawela
*3-11912345678_16/01/08-00:13:35Z_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/08-00:13:35Y_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/08-00:13:35X_syncing file systems... done
*3-11912345678_16/01/08-00:13:35W_au02 syslogd: going down on signal 15
*3-11912345678_16/01/08-00:04:08V_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/07-23:47:25S_syncing file systems... done
*3-11912345678_16/01/07-23:46:41R_au02 syslogd: going down on signal 15
*3-11912345678_16/01/07-23:41:48y_Host: Solaris running
*3-11912345678_16/01/07-23:35:34Q_root@au02:~# Jan 7 23:37:21 au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/07-23:24:08z_Host: Solaris running
*3-11912345678_16/01/07-23:22:28U_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/07-23:22:28T_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/07-23:18:41y_Power to /SYS has been turned on by: Web session
*3-11912345678_16/01/07-22:57:19z_Host: Solaris running
*3-11912345678_16/01/07-22:55:34P_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/07-22:55:34O_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/07-22:51:45z_Power to /SYS has been turned on by: Web session
*3-11912345678_16/01/07-22:28:52_ereport.chassis.sp.restart@/SYS/MB/SP
*3-11912345678_16/01/07-22:28:19_ereport.chassis.tli.ok@/SYS
*3-11912345678_16/01/07-22:27:53N_syncing file systems... done
*3-11912345678_16/01/07-22:26:46M_au02 syslogd: going down on signal 15
*3-11912345678_16/01/07-22:24:17z_SP is about to reboot
*3-11912345678_16/01/07-22:24:15z_upgrade to version 3.2.5.6.b succeeded
*3-11912345678_16/01/02-23:42:41L_au02 ufs: WARNING: realloccg: /backup: file system full
*3-11912345678_16/01/01-02:25:52K_au02 ufs: WARNING: alloc: /backup: file system full
*3-11912345678_15/12/22-15:05:41J_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11901234567_15/12/20-17:53:28a_au02 ^Disconnected command timeout for Target 9
*3-11901234567_15/10/08-06:59:12_Fault ID: c7e0af47-2b56-4e97-b35f-e7990913bedc PCIEX-8000-8R Major
*3-11912345678_15/10/08-06:33:20z_Fault PCIEX-8000-8R - PCIEX subsystem problem on /SYS/MB
*3-11912345678_15/10/08-06:33:15_ereport.io.pciex.rc.epkt@/HOST
*3-11912345678_15/10/07-19:27:17F_au02 scsi: WARNING: /pci@300/pci@1/pci@0/pci@2/scsi@0 (mpt_sas1):
*3-11901234567_15/10/05-00:27:_reboot system boot
*3-11912345678_15/10/05-00:01:16z_Host: Solaris running
*3-11912345678_15/10/04-23:48:15y_Power to /SYS has been turned on by: Web session
*3-11912345678_15/10/04-23:30:06_ereport.chassis.post.serviceprocessor@/SYS/MB/SP/PHY0_LINKSTATUS
*3-11912345678_15/10/04-23:29:40_ereport.sp.boot-cold@/SYS/MB/SP
*3-11912345678_15/10/04-23:29:19_ereport.chassis.tli.ok@/SYS
Attachments