Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1611932.1
Update Date:2017-11-03
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1611932.1 :   db - the Summary Tool metadata query tool  


Related Items
  • Sun SPARC Enterprise T5120 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>CMT Servers
  •  




Oracle Confidential PARTNER - Available to partners (SUN).
Reason: cores3 tools are internal only

Applies to:

Sun SPARC Enterprise T5120 Server - Version Not Applicable and later
Information in this document applies to any platform.

Purpose

This lists how to run queries on metadata from explosum & snapper output on cores3 servers.

Details

The Explosum & Snapper tools gather hardware related metadata from an Explorer & ILOM Snapshot data.  These tools are targeted for VSP products, but can be used on explorers & snapshots from other SPARC or X64 products.

File /share/summarytools/log.txt contains a log of Explorers & Snapshots that the tools were run against on the ISDE server.

These tools will also store FRU & event data for most platform types if the Explorer contains a valid date, Serial number, & if run from an SR directory on ISDE. Each server will contain it's own set of entries as shown below (Sample Raw Data). The first line contains a list of Explorer/Snapshot dates with the associated SR#. The second section contains a list of installed FRUs & associated FRU data like it's serial number. If multiple FRU data is listed, then the later entries indicate the FRUs that have been replaced/moved. The final type of data is the ordered event list of the last 256 events. This lists ILOM & Solaris reboots (listing FW version), ILOM FW upgrades, some ereports & faults, & kernel Warnings. This data is used in the timelines listed at the end of Explosum's & Snapper's Summaries which provides the TSE a view of combined Explorer, Snapshot, & older SR data. The db tool can be used to query this data.

The man page data for the db tool is as follows:

   db          Scan db for problems & sizes
   db "?"      Command syntax
   db MultiFRU  [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
               List Systems with multiple FRU replacements
   db Replaced  [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
               List Systems/FRU replacements
   db ListFRU   [matchString/Platform/Ser#/SR/date] [matchString/date] [matchString]
               List a System's FRUs  [List only matching strings/params]
   db FRU  Platform/FRUSer#/SR/fruType/date  [fruType/matchString/date]
               List FRU matches [or specific FRU] that contain parameters
   db SR SR#/Ser#  [matchString/date] [matchString/date]
               List systems that are associated with SR#  
   db Chassis Ser#   List all information for a Chassis Serial #
   db Platform/Ser#/matchString  [matchString/date]  [matchString/date] [matchString]
               List events with matching string
       
Notes:
1.  Parameters are pre-screened for dates, SR #, Platform type, Chassis or FRU serial number.  
      If none of these, is then determined to be a keyword to search events.  
      All event related parameters are ORed (listed if one matches) for each event,
       but all FRU, chassis & date parameters are ANDed (listed if all match).

2.  Date syntax = yy/mm  or  yy/mm/dd  or  yy/mm/dd-hh:mm
      If 2 dates input, the first is matches if an entry is older & if 2nd newer

3.  Valid platform names are: T5120, T5220, N5220, T5140, T5240, N5440, T5440, T6320, T6340, C3260,
        T3-1, N3-1, T3-2, T3-4, T3-1B, N31BA, T4-1, N4-1, T4-2, N4-2, T4-4, T4-1B,
        T5-2, T5-4, T5-8, T5-1B, M5-32,
        M3000, M4000, M5000, M8000, M9000, M10.1, M10.4, M104S
      T4 or T5 will match all T4 or T5 platforms.

4.  FRU names must be the same as listed in the Explorer or Snapshot including '/'s.  The only FRU names
      without '/'s are:
    "MB", "FB", "SASBP", "MIDPLANE", "CMM", "RIO", "FIO", "RCSA", "SIB", "DBP", "PDB", "PADCRD"
    "CM#", "PS#", "NEM#", "SASBP#", "P#", "HDD#", "PM#"

 

Some examples db are:

List the FRUs related to Chassis Serial number & dates detected in system:

amogg0021% /share/summarytools/db ListFRU AK00121322
db revision 2.15  _ListFRU_ f__ __ h_AK00121322_  __ e__  __

 FRUs  T5-2    AK00121322 P0/M0            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0HEE

 FRUs  T5-2    AK00121322 P0/M1            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0JM6

 FRUs  T5-2    AK00121322 P0/M2            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0JL8

 FRUs  T5-2    AK00121322 P0/M3            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0JM4

 FRUs  T5-2    AK00121322 P1/M0            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1320UG0GJE

 FRUs  T5-2    AK00121322 P1/M1            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0JNH

 FRUs  T5-2    AK00121322 P1/M2            - 14/03/13-13:59:27     Oracle Corpo                           7064940      465769T+1321UG0HDV
 FRUs  T5-2    AK00121322 P1/M2            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0HET

 FRUs  T5-2    AK00121322 P1/M3            - 14/03/13-13:59:27     Oracle Corpo                           7064940      465769T+1321UG0HET
 FRUs  T5-2    AK00121322 P1/M3            - 13/11/20-19:28:45     Oracle Corpo                           7064940      465769T+1321UG0HDV

 FRUs  T5-2    AK00121322 P0/M0/B0/C0/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211748CB05

 FRUs  T5-2    AK00121322 P0/M0/B0/C1/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211718CAF9

 ...

 FRUs  T5-2    AK00121322 P1/M2/B0/C0/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728C37558
 FRUs  T5-2    AK00121322 P1/M2/B0/C0/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211788CAFC

 FRUs  T5-2    AK00121322 P1/M2/B0/C1/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728237556
 FRUs  T5-2    AK00121322 P1/M2/B0/C1/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211758CB00

 FRUs  T5-2    AK00121322 P1/M2/B1/C0/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113273D4CAB71
 FRUs  T5-2    AK00121322 P1/M2/B1/C0/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211718CB03

 FRUs  T5-2    AK00121322 P1/M2/B1/C1/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728737539
 FRUs  T5-2    AK00121322 P1/M2/B1/C1/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211768CB02

 FRUs  T5-2    AK00121322 P1/M3/B0/C0/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211788CAFC
 FRUs  T5-2    AK00121322 P1/M3/B0/C0/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728C37558

 FRUs  T5-2    AK00121322 P1/M3/B0/C1/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211758CB00
 FRUs  T5-2    AK00121322 P1/M3/B0/C1/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728237556

 FRUs  T5-2    AK00121322 P1/M3/B1/C0/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211718CB03
 FRUs  T5-2    AK00121322 P1/M3/B1/C0/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113273D4CAB71

 FRUs  T5-2    AK00121322 P1/M3/B1/C1/D0   - 14/03/13-13:59:27     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD0113211768CB02
 FRUs  T5-2    AK00121322 P1/M3/B1/C1/D0   - 13/11/20-19:28:45     Hynix Semico      HMT31GR7CFR4A-PB     7042208      00AD01132728737539

 FRUs  T5-2    AK00121322 MB               - 14/03/13-13:59:27     Oracle Corpo                           7076601      465769T+1335UL06A9
 FRUs  T5-2    AK00121322 MB               - 13/11/20-19:28:45     Oracle Corpo                           7076601      465769T+1324UL059D

 FRUs  T5-2    AK00121322 MB/SP            - 13/11/20-19:28:45     Oracle Corpo                           7066335      465769T+1323UF09H9

 FRUs  T5-2    AK00121322 CM0              - 13/11/20-19:28:45     Oracle Corpo                           7076601      465769T+1324UL059D


List Chassis Serial #s related to SR #(s):
amogg0021% /share/summarytools/db SR AK00121322
db revision 2.15  _SR_ f__ __ h_AK00121322_  __ e__  __

 SRs  T5-2    AK00121322 -  3-8698079871 14/03/13-13:59:27,  3-7675377660 13/11/20-19:28:45


List events between a date range:
amogg0021% /share/summarytools/db 13/12 13/11 VCORE_POK
db revision 2.10  _13/12_ _13/11_ _VCORE_POK_ __

  T3-1    1045BDR17C  3-8124433291    13/11/20-01:25:33 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH

  T3-1    1115BDR4DA  3-8062200781    13/11/07-04:20:15 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH

  T3-1    1116BDR5C2  3-8074646081    13/11/08-22:45:42 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH

  T3-1    1142BDR6C8  3-8085715381   13/11/12-09:04:40b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP0/VCORE_POK
  T3-1    1142BDR6C8  3-8085715381   13/11/12-08:32:18b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP0/VCORE_POK
  T3-1    1142BDR6C8  3-8085715381   13/11/11-13:48:35a ereport.chassis.power.glitch-fatal@/sys/mb  /SYS/MB/CMP0/VCORE_POK_GLITCH

  T3-2    1102BDR70A  3-8172302291    13/11/30-16:16:59 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH
  T3-2    1102BDR70A  3-8172302291    13/11/16-14:15:00 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH

  T3-2    1126BDRA21  3-8076630651    13/11/20-13:21:51 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH
  T3-2    1126BDRA21  3-8076630651    13/11/10-07:16:13 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH

  T4-1    1230BDYAA1  3-8048491001   13/11/04-16:46:31b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP0/VCORE_POK
  T4-1    1230BDYAA1  3-8048491001   13/11/04-16:28:36b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP0/VCORE_POK
  T4-1    1230BDYAA1  3-8048491001   13/11/03-22:35:52a ereport.chassis.power.glitch-fatal@/sys/mb  /SYS/MB/CMP0/VCORE_POK_GLITCH

  T4-2    1150BDY02C  3-8170645441   13/11/29-04:28:00a 00  ereport.chassis.power.glitch-fatal@/sys/mb  /SYS/MB/CMP0/VCORE_POK_GLITCH

  T4-2    1240BDY37C  3-8042637471   13/11/03-04:12:43b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP0/VCORE_POK
  T4-2    1240BDY37C  3-8042637471   13/11/03-03:13:53a ereport.chassis.power.glitch-fatal@/sys/mb  /SYS/MB/CMP0/VCORE_POK_GLITCH

  T4-2    1242BDY855  3-8076318861   13/11/10-05:31:11b ereport.chassis.poweron.fail-asserted@/sys/mb  /SYS/MB/CMP1/VCORE_POK
  T4-2    1242BDY855  3-8076318861   13/11/10-00:57:38a ereport.chassis.power.glitch-fatal@/sys/mb  /SYS/MB/CMP1/VCORE_POK_GLITCH

  T4-2    1249BDYC85  3-8130414056    13/11/20-19:57:06 ereport.chassis.power.glitch-fatal@/SYS/MB   /SYS/MB/CMP0/VCORE_POK_GLITCH


List the chassis which contains (or contained) a FRU serial #:
amogg0021% /share/summarytools/db FRU 1125B2099P
db revision 2.10  _FRU_ _1125B2099P_ __ __

 FRUs  T3-1    1127BDRD13               MB -      5030 CELESTI             541-3857 1005LCB-1125B2099P

 

List T5-2 servers that had FRU multiple non-DIMM FRU replacements/swaps after February 2014:
amogg0021% /share/summarytools/db MultiFRU T5-2 14/03
db revision 2.15  _MultiFRU_ f__ __ h_T5-2_  __ e__  __

 MultiRep FRUs  T5-2    AK00121322 P1/M2            - 14/03/13-13:59:27     Oracle Corpo                           465769T+1321UG0HDV
 Replaced FRUs  T5-2    AK00121322 P1/M3            - 14/03/13-13:59:27     Oracle Corpo                           465769T+1321UG0HET

 Replaced FRUs  T5-2    AK00121322 MB               - 14/03/13-13:59:27     Oracle Corpo                           465769T+1335UL06A9

 MultiRep FRUs  T5-2    AK00131878 PS0              - 14/03/19-10:38:06     Emerson Netw                           476856F+1217CD00FE
 Replaced FRUs  T5-2    AK00131878 PS1              - 14/03/19-10:38:06     Emerson Netw                           476856F+1225CD01GA

 MultiRep FRUs  T5-2    AK00142748 MB               - 14/03/02-00:19:       Oracle Corporati                       465769T+1324UL053V
 Replaced FRUs  T5-2    AK00142748 FB               - 14/03/02-00:19:       9615 HON HAI PRE                       464507L+132212026W

 MultiRep FRUs  T5-2    AK00169587 P1/M2            - 14/03/20-11:11:       Oracle Corporati                       465769T+1347UG16TK
 Replaced FRUs  T5-2    AK00169587 P1/M3            - 14/03/20-11:11:       Oracle Corporati                       465769T+1347UG16T7

 Replaced FRUs  T5-2    AK00169587 MB               - 14/03/20-11:11:       Oracle Corporati                       465769T+1322UL04X0

 

List T5-8 servers that had FRU multiple non-DIMM FRU replacements/swaps between Nov 2013 & Dec 15 2013:
amogg0021% db MultiFRU T5-8 13/12/15 13/11
db revision 2.11  _MultiFRU_ _T5-8_ _13/12/15_ _13/11_

 MultiRep FRUs  T5-8    AK00097225 MB               - 13/12/02-21:28:22    Oracle Corpo                           465769T+13235203PY
 Replaced FRUs  T5-8    AK00097225 P2               - 13/11/27-16:54:11    Oracle Corpo                           465769T+133088047H

 MultiRep FRUs  T5-8    AK00136161 P1               - 13/11/26-10:42:      Oracle Corpo                           465769T+13318804AE
 Replaced FRUs  T5-8    AK00136161 PS0              - 13/11/26-10:42:      POWER ONE                              465776G+1314B204BE
 Replaced FRUs  T5-8    AK00136161 PS1              - 13/12/03-12:33:48    POWER ONE                              465776G+1314B204V6

 MultiRep FRUs  T5-8    AK00136654 P0               - 13/11/26-10:41:      Oracle Corpo                           465769T+13068800MW
 Replaced FRUs  T5-8    AK00136654 P1               - 13/11/26-10:41:      Oracle Corpo                           465769T+1252880057
 Replaced FRUs  T5-8    AK00136654 P2               - 13/11/26-10:41:      Oracle Corpo                           465769T+13248803JY
 Replaced FRUs  T5-8    AK00136654 P3               - 13/11/26-10:41:      Oracle Corpo                           465769T+13038800F7

 

List T5-2 servers that had FRU replacements between March 15 2014 & March 21. (If a PM moves, then all it's DIMMs are also considered replaced):
amogg0021% db Replaced T5-2 14/03/15 14/03/22
db revision 2.16  _Replaced_ f__ __ h_T5-2_  __ e__  __ d_14/03/15_ _14/03/22_

 Replaced FRUs  T5-2    AK00131878 PS0              - 14/03/19-10:38:06     Emerson Netw                           476856F+1217CD00FE

 Replaced FRUs  T5-2    AK00131878 PS1              - 14/03/19-10:38:06     Emerson Netw                           476856F+1225CD01GA

 Replaced FRUs  T5-2    AK00133969 MB               - 14/03/17-15:49:       Oracle Corporati                       465769T+1324UL054E

 Replaced FRUs  T5-2    AK00149066 MB               - 14/03/21-17:35:       Oracle Corporati                       465769T+1324UL055T

 Replaced FRUs  T5-2    AK00169587 P1/M2            - 14/03/20-11:11:       Oracle Corporati                       465769T+1347UG16TK

 Replaced FRUs  T5-2    AK00169587 P1/M3            - 14/03/20-11:11:       Oracle Corporati                       465769T+1347UG16T7

 Replaced FRUs  T5-2    AK00169587 MB               - 14/03/20-11:11:       Oracle Corporati                       465769T+1322UL04X0

 Replaced FRUs  T5-2    AK00169587 P1/M2/B0/C0/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261176AB23

 Replaced FRUs  T5-2    AK00169587 P1/M2/B0/C1/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261146AB22

 Replaced FRUs  T5-2    AK00169587 P1/M2/B1/C0/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261176AB29

 Replaced FRUs  T5-2    AK00169587 P1/M2/B1/C1/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261146AB2A

 Replaced FRUs  T5-2    AK00169587 P1/M3/B0/C0/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261146AB28

 Replaced FRUs  T5-2    AK00169587 P1/M3/B0/C1/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261126AB2A

 Replaced FRUs  T5-2    AK00169587 P1/M3/B1/C0/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261156AB2D

 Replaced FRUs  T5-2    AK00169587 P1/M3/B1/C1/D0   - 14/03/20-11:11:       Hynix Semiconduc  HMT31GR7CFR4A-PB     00AD0113261166AB29

 Replaced FRUs  T5-2    AK00174588 P0/M3/B0/C0/D0   - 14/03/20-15:50:17     Hynix Semico      HMT42GR7AFR4A-PB     00AD011405400281D5

 

Sample Raw Data:

T5-1 /AK00208327 (3-11912345678_16/01/11-13:44:07) (3-11901234567_15/12/22-15:12:) (3-10312345678_15/04/29-09:56:) (3-10312345678_15/03/10-23:20:) (3-9910123456_14/11/23-11:10:)
P0/M0 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WX5_7064940-03)
P0/M1 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WG4_7064940-03)
P0/M2 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WMK_7064940-03)
P0/M3 (14/11/23-11:10:_Oracle Corporati__465769T+1414UG1WML_7064940-03)
MB (14/11/23-11:10:_Oracle Corporati__465769T+1413U4004X_7088094-03)
MB/SP (14/11/23-11:10:_Oracle Corporati__465769T+1410UF0JYF_7066335-01)
FB (14/11/23-11:10:_Oracle Corporati__464507N+1406HH002F_7057262-02)
HDD0 (14/11/23-11:10:_HITACHI_H109030SESUN300G_001408CTA8GN_)
HDD1 (14/11/23-11:10:_HITACHI_H109030SESUN300G_001408CS7MKF_)
SASBP (14/11/23-11:10:_Oracle Corporati__464507L+14011100BB_7039459-02)
PS0 (14/11/23-11:10:_Emerson Network __476856F+1409CD00LM_7060596)
PS1 (14/11/23-11:10:_Emerson Network __476856F+1409CD00LN_7060596)
P0/M0/B0/C0/D0 (16/01/11-13:44:07:_Samsung_M393B1K70DH0-YK0_00CE0314101584323D_7042208) (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314101584323C_7042208)
P0/M0/B0/C1/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE031410158432C3_7042208)
...
P0/M3/B1/C0/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314111586F660_7042208)
P0/M3/B1/C1/D0 (14/11/23-11:10:_Samsung_M393B1K70DH0-YK0_00CE0314111586EDFE_7042208)
CM0 (16/01/11-13:44:07_Oracle Corpo__465769T+1413U4004X_7088094)
SP (16/01/11-13:44:07_Oracle Corpo__465769T+1410UF0JYF_7066335)
*3-11912345678_16/01/09-12:40:44r_au02 fbt: [ID 795213 kern.warning] WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/09-12:40:44a_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/09-12:39:43b_au02 igb: [ID 611667 kern.warning] WARNING: igb0: ioctl 82576 map not kawela
*3-11912345678_16/01/08-00:13:35Z_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/08-00:13:35Y_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/08-00:13:35X_syncing file systems... done
*3-11912345678_16/01/08-00:13:35W_au02 syslogd: going down on signal 15
*3-11912345678_16/01/08-00:04:08V_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/07-23:47:25S_syncing file systems... done
*3-11912345678_16/01/07-23:46:41R_au02 syslogd: going down on signal 15
*3-11912345678_16/01/07-23:41:48y_Host: Solaris running
*3-11912345678_16/01/07-23:35:34Q_root@au02:~# Jan 7 23:37:21 au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11912345678_16/01/07-23:24:08z_Host: Solaris running
*3-11912345678_16/01/07-23:22:28U_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/07-23:22:28T_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/07-23:18:41y_Power to /SYS has been turned on by: Web session
*3-11912345678_16/01/07-22:57:19z_Host: Solaris running
*3-11912345678_16/01/07-22:55:34P_SunOS Release 5.11 Version 11.2 64-bit
*3-11912345678_16/01/07-22:55:34O_OpenBoot 4.38.1, 127.0000 GB memory available, Serial #106358986.
*3-11912345678_16/01/07-22:51:45z_Power to /SYS has been turned on by: Web session
*3-11912345678_16/01/07-22:28:52_ereport.chassis.sp.restart@/SYS/MB/SP
*3-11912345678_16/01/07-22:28:19_ereport.chassis.tli.ok@/SYS
*3-11912345678_16/01/07-22:27:53N_syncing file systems... done
*3-11912345678_16/01/07-22:26:46M_au02 syslogd: going down on signal 15
*3-11912345678_16/01/07-22:24:17z_SP is about to reboot
*3-11912345678_16/01/07-22:24:15z_upgrade to version 3.2.5.6.b succeeded
*3-11912345678_16/01/02-23:42:41L_au02 ufs: WARNING: realloccg: /backup: file system full
*3-11912345678_16/01/01-02:25:52K_au02 ufs: WARNING: alloc: /backup: file system full
*3-11912345678_15/12/22-15:05:41J_au02 fbt: WARNING: couldn't allocate FBT table for module oracleacfs
*3-11901234567_15/12/20-17:53:28a_au02 ^Disconnected command timeout for Target 9
*3-11901234567_15/10/08-06:59:12_Fault ID: c7e0af47-2b56-4e97-b35f-e7990913bedc PCIEX-8000-8R Major
*3-11912345678_15/10/08-06:33:20z_Fault PCIEX-8000-8R - PCIEX subsystem problem on /SYS/MB
*3-11912345678_15/10/08-06:33:15_ereport.io.pciex.rc.epkt@/HOST
*3-11912345678_15/10/07-19:27:17F_au02 scsi: WARNING: /pci@300/pci@1/pci@0/pci@2/scsi@0 (mpt_sas1):
*3-11901234567_15/10/05-00:27:_reboot system boot
*3-11912345678_15/10/05-00:01:16z_Host: Solaris running
*3-11912345678_15/10/04-23:48:15y_Power to /SYS has been turned on by: Web session
*3-11912345678_15/10/04-23:30:06_ereport.chassis.post.serviceprocessor@/SYS/MB/SP/PHY0_LINKSTATUS
*3-11912345678_15/10/04-23:29:40_ereport.sp.boot-cold@/SYS/MB/SP
*3-11912345678_15/10/04-23:29:19_ereport.chassis.tli.ok@/SYS

 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback