Applies to:SPARC T4-1SPARC T3-4 SPARC T3-2 SPARC T3-1 SPARC T4-4 SPARC PurposeTo clarify how the on board LSI controller firmware should be upgraded Details
The T3-1, T3-2, T4--1, T4-2 systems use onboard SAS controllers and T3-4 and T4-4 use REM (RAID Expansion Module) LSI disk controllers. Oracle does not recommend customers go to lsi.com for fw updates for our onboard SAS controllers Oracle does not qualify every version of fw that LSI releases In the event Firmware updates for the onboard SAS controllers are released they will be in the form of a specific LSI firmware patch and must be acquired from Oracle’s Sun System Firmware Release Hub Query the support portal for an LSI patch for the related platform. Another option is to check the "patch readme's and downloads" section for the related platform in the System Handbook Firmware applied to the onboard SAS controllers from any other location or any vendor other than Oracle is not supported NOTE: System Firmware patches do not contain the SAS controller firmware
For systems that use REM LSI SAS controllers such as T3-4 and T4-4 go the LSI website to obtain the firmware http://www.lsi.com/sep/pages/oracle/sg_x_sas6-rem-z.aspx
Please see ....How to Find Sun System Firmware (PROM, OBP, LSI, BIOS, XCP) Patches in My Oracle Support (MOS) (Doc ID 1294603.1) Attachments This solution has no attachment |
||||||||||||||
|