Applies to:Sun ZFS Storage 7120 - Version All Versions and laterOracle ZFS Storage ZS3-4 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later 7000 Appliance OS (Fishworks) PurposeProvide additional information for message ID: SAS-8000-25 DetailsType: Fault fault.io.sas.cable.wrong-receptacle Severity: Minor Description A Serial Attached SCSI (SAS) cable is connected to the wrong receptacle. Automated Response None Impact Degradation in service due to subsystem resources being removed from operation. Suggested Action for System Administrator Prior to submitting a service request the storage/system administrator should perform the following SAS cable check:
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
***Checked for relevance on 25-MAY-2018*** References<NOTE:1432269.2> - Information Center: Sun ZFS Storage Appliances<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI <NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center Attachments This solution has no attachment |
||||||||||||||||
|