![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1593746.1 : Sun ZFS Storage Appliance: SAS-8000-7H - Unbalanced SAS interface to storage enclosure
In this Document
Applies to:Oracle ZFS Storage ZS3-4 - Version All Versions and laterOracle ZFS Storage ZS3-2 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later Sun ZFS Storage 7320 - Version All Versions and later Sun ZFS Storage 7120 - Version All Versions and later 7000 Appliance OS (Fishworks) PurposeProvide additional information for message ID: SAS-8000-7H ScopeDetailsType: Fault fault.io.sas.hba.unbalanced-depth Severity: Minor Description The chain of storage enclosures connected to an HBA receptacle is longer than chains in an alternate path. Too many cables are attached to same sas expander. One or more cables is redundant or incorrect Automated Response None Impact Degradation in service due to subsystem resources removed from operation. Unbalanced storage enclosure chain depths may cause degraded system performance.
Suggested Action for System Administrator Prior to submitting a service request the storage/system administrator should perform the following SAS cable check:
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
***Checked for relevance on 25-MAY-2018*** References<NOTE:1432269.2> - Information Center: Sun ZFS Storage Appliances<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI <NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center Attachments This solution has no attachment |
||||||||||||||||||
|