![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1593729.1 : Sun ZFS Storage Appliance: SAS-8000-43 - SAS cable configuration exceeds maximum number of connections
In this Document
Applies to:Sun ZFS Storage 7320 - Version All Versions and laterSun ZFS Storage 7120 - Version All Versions and later Oracle ZFS Storage ZS3-2 - Version All Versions and later Oracle ZFS Storage ZS3-4 - Version All Versions and later Sun ZFS Storage 7420 - Version All Versions and later 7000 Appliance OS (Fishworks) PurposeProvide additional information for message ID: SAS-8000-43 ScopeDetailsType: Fault, fault.io.sas.cable.too-deep Severity: Major Description The maximum number of supported storage enclosures has been exceeded. The SAS cable on an HBA has 7 hops, maximum expected is 6.
Automated Response None
Impact Misconfigured SAS cable connections and too many storage enclosures may cause system degradation and performance issues.
Suggested Action for System Administrator Prior to submitting a service request the storage/system administrator should perform the following SAS cable check:
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
***Checked for relevance on 25-MAY-2018*** References<NOTE:1019887.1> - Sun Storage 7000 Unified Storage System: How to Collect a Support Bundle using the BUI or CLI<NOTE:1416406.1> - Sun ZFS Storage Appliances Troubleshooting Resource Center <NOTE:1432269.2> - Information Center: Sun ZFS Storage Appliances Attachments This solution has no attachment |
||||||||||||||||||
|